CT urography: the end of IVU?
- PMID: 18536872
- DOI: 10.1007/s11547-008-0281-6
CT urography: the end of IVU?
Abstract
A review of the literature on the diagnostic accuracy of multidetector computed tomography urography (MDCTU) and intravenous urography (IVU) reveals a lack of comparative studies. However, the available data indicate that MDCTU has a high diagnostic accuracy. MDCTU is also preferred by patients, as it does not require bowel preparation. Full acceptance of this technique by the urologist will depend on optimisation of the communication process with a careful selection of the images to be transmitted. MDCTU has a higher cost than IVU but allows some diagnostic algorithms to be simplified. The real concern potentially limiting the widespread use of MDCTU is its higher radiation dose when compared with IVU. Although low-dose protocols will soon be available, a substantial dose reduction can already be achieved by tailoring MDCTU to the clinical problem rather than using a standardised approach. Our analysis indicates that IVU will definitely lose any residual role it may still have. In our department, the last urographic procedure was performed in May 2006.
Similar articles
-
Improved visualization of the urinary tract in multidetector CT urography (MDCTU): analysis of individual acquisition delay and opacification using furosemide and low-dose test images.J Comput Assist Tomogr. 2006 Sep-Oct;30(5):751-7. doi: 10.1097/01.rct.0000224631.25198.ed. J Comput Assist Tomogr. 2006. PMID: 16954923
-
Accuracy of intermediate dose of furosemide injection to improve multidetector row CT urography.Eur J Radiol. 2008 May;66(2):253-61. doi: 10.1016/j.ejrad.2007.06.003. Epub 2007 Jul 23. Eur J Radiol. 2008. PMID: 17646072
-
Cost-effectiveness analysis (CEA) of intravenous urography (IVU) and unenhanced multidetector computed tomography (MDCT) for initial investigation of suspected acute ureterolithiasis.Acta Radiol. 2008 Mar;49(2):222-9. doi: 10.1080/02841850701708304. Acta Radiol. 2008. PMID: 18300151 Clinical Trial.
-
Unenhanced helical computed tomography vs intravenous urography in patients with acute flank pain: accuracy and economic impact in a randomized prospective trial.Eur Radiol. 2003 Nov;13(11):2513-20. doi: 10.1007/s00330-003-1937-1. Epub 2003 Jul 24. Eur Radiol. 2003. PMID: 12898174 Review.
-
The current status of CT urography (2002).Crit Rev Comput Tomogr. 2002;43(3):219-41. Crit Rev Comput Tomogr. 2002. PMID: 12137360 Review. No abstract available.
Cited by
-
Magnetic resonance urography vs computed tomography urography in the evaluation of patients with haematuria.Radiol Med. 2013 Oct;118(7):1184-98. doi: 10.1007/s11547-013-0955-6. Epub 2013 Jun 25. Radiol Med. 2013. PMID: 23801402
-
Diagnostic value of 64-slice spiral computed tomography imaging of the urinary tract during the excretory phase for urinary tract obstruction.Exp Ther Med. 2017 Nov;14(5):4761-4766. doi: 10.3892/etm.2017.5176. Epub 2017 Sep 21. Exp Ther Med. 2017. PMID: 29201177 Free PMC article.
-
64-Slice CT urography: 30 months of clinical experience.Radiol Med. 2010 Sep;115(6):920-35. doi: 10.1007/s11547-010-0567-3. Epub 2010 Jun 23. Radiol Med. 2010. PMID: 20574699 English, Italian.
-
Computed tomography urography with corticomedullary phase can exclude urinary bladder cancer with high accuracy.BMC Urol. 2022 Apr 12;22(1):60. doi: 10.1186/s12894-022-01009-4. BMC Urol. 2022. PMID: 35413901 Free PMC article.
-
Prolonged CT urography in duplex kidney.BMC Urol. 2016 May 13;16(1):21. doi: 10.1186/s12894-016-0139-5. BMC Urol. 2016. PMID: 27177584 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical