Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1991 May;57(5):1528-34.
doi: 10.1128/aem.57.5.1528-1534.1991.

Comparative study of commercial 4-methylumbelliferyl-beta-D-glucuronide preparations with the Standard Methods membrane filtration fecal coliform test for the detection of Escherichia coli in water samples

Affiliations
Comparative Study

Comparative study of commercial 4-methylumbelliferyl-beta-D-glucuronide preparations with the Standard Methods membrane filtration fecal coliform test for the detection of Escherichia coli in water samples

D L Clark et al. Appl Environ Microbiol. 1991 May.

Abstract

The performance capabilities of two commercial 4-methylumbelliferyl-beta-D-glucuronide preparations were evaluated for the detection of Escherichia coli from water samples. Eighty-three water samples were collected from a treated water reservoir, and 32 samples were collected from untreated surface water. There was a statistically significant difference between the two commercial preparations compared with the Standard Methods membrane filtration fecal coliform (MFC) method for the detection of E. coli from treated water samples. However, there was no difference between the two methods and the MFC test for E. coli detection from the untreated surface water samples. The disagreement between the two commercial products and the MFC method was primarily due to the occurrence of false-negative results with the two commercial products. The data indicate that the occurrence of false-negative samples could be attributed to impaired substrate specificity and sensitivity of the two tests for E. coli detection. There was no apparent relationship between the occurrence of false-negative results and heterotrophic plate counts in samples.

PubMed Disclaimer

Comment in

  • Defined substrate technology test for E. coli.
    Edberg SC. Edberg SC. Appl Environ Microbiol. 1991 Nov;57(11):3403-4. doi: 10.1128/aem.57.11.3403-3404.1991. Appl Environ Microbiol. 1991. PMID: 1781699 Free PMC article. No abstract available.

References

    1. Boll Ist Sieroter Milan. 1982;61(5):441 - PubMed
    1. Appl Environ Microbiol. 1985 Dec;50(6):1383-7 - PubMed
    1. J Clin Microbiol. 1990 Apr;28(4):803-5 - PubMed
    1. Appl Environ Microbiol. 1990 Feb;56(2):366-9 - PubMed
    1. Appl Environ Microbiol. 1977 Jun;33(6):1259-64 - PubMed

Publication types