Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Mar;22(2):365-74.
doi: 10.1519/JSC.0b013e3181635b2e.

The 30-15 intermittent fitness test: accuracy for individualizing interval training of young intermittent sport players

Affiliations

The 30-15 intermittent fitness test: accuracy for individualizing interval training of young intermittent sport players

Martin Buchheit. J Strength Cond Res. 2008 Mar.

Abstract

The objective of this study was to gather evidence supporting the accuracy of the 30-15 Intermittent Fitness Test (30-15IFT) for individualizing interval training of young intermittent sport players. In 59 young intermittent sport players (age, 16.2 +/- 2.3 years), we observed the relationships between the maximal running speed (MRS) reached at the end of the 30-15IFT (MRS30-15IFT) and physiological variables elicited by shuttle intermittent runs, including maximal oxygen uptake, explosive power of lower limbs, and the ability to repeat intense exercise bouts through cardiorespiratory recovery kinetics during exercise. To observe the capacity of the 30-15IFT to prescribe suitable running intensities for interval training sessions, we compared heart rates (HRs) reached during 3 series of intermittent runs, where distances were set according to the MRS30-15IFT and to MRS reached with 2 popular continuous field tests: the University of Montreal track test and the 20-m shuttle run test. The results show that the MRS30-15IFT is significantly correlated with all physiological variables elicited by shuttle intermittent runs (P < 0.05). Although mean HR were not different among the 3 series of intermittent runs, HR recorded during the runs based on MRS30-15IFT presented significantly less interindividual variation than when the continuously determined MRS were used as reference speeds. In conclusion, we can say that the 30-15IFT leads to an MRS that simultaneously takes into account various physiological qualities elicited when performing shuttle intermittent runs. For scheduling interval training sessions, the MRS30-15IFT appears to be an accurate reference speed for getting players with different physiological profiles to a similar level of cardiorespiratory demand and thus for standardizing training content.

PubMed Disclaimer