Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Oct;106(4):477-82.
doi: 10.1016/j.tripleo.2008.02.003. Epub 2008 Jun 13.

Fixation properties of a biodegradable "free-form" osteosynthesis plate

Affiliations
Comparative Study

Fixation properties of a biodegradable "free-form" osteosynthesis plate

Petteri Väänänen et al. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008 Oct.

Abstract

The Inion FreedomPlate, a "free-form" osteosynthesis plate, is a biodegradable plate with just pilot holes for drilling. The construction of the plate allows the surgeon a placement of screws in optimal position. The screw heads can either be countersunk into the plate or cut off. Furthermore, the plate can be cut and contoured to match the bone. The aim of this study was to determine the mechanical properties of the Inion FreedomPlate compared to a conventional biodegradable plate. Acrylic pipes were fixed together with plates and screws. Tensile and cantilever bending tests were performed to measure the fixation properties. In the tensile test, the samples were loaded with a constant speed of 5 mm/min until failure of fixation. The yield load, maximum failure load, and initial stiffness were recorded, and the failure mode was visually determined. In the cantilever bending test, the samples were loaded with a constant speed of 50 mm/min (with a moment arm of 45 mm) until failure of fixation. The yield bending moment and initial stiffness were recorded, and the failure mode was determined. The results of the study show that the new free-form plate provides at least as strong fixation as the tested conventional biodegradable plate. No clinically relevant difference was found between free-form plates fixed with into-the-plate countersunk screws and those fixed with screws without heads.

PubMed Disclaimer

Publication types

LinkOut - more resources