Relationship of shear stress with in-stent restenosis: bare metal stenting and the effect of brachytherapy
- PMID: 18556077
- DOI: 10.1016/j.ijcard.2008.02.006
Relationship of shear stress with in-stent restenosis: bare metal stenting and the effect of brachytherapy
Abstract
Background: The association of shear stress (SS) with in-stent restenosis after bare metal stenting is not clear. We investigated the significance of SS on predicting areas with neointima thickness (NT) in humans and the effect of vascular brachytherapy (VBT) following coronary artery stenting on the relationship of SS with NT.
Methods: By using coronary angiography and intravascular ultrasound, we performed three-dimensional (3D) artery and stent reconstruction in 14 patients at 8-month follow-up after bare metal stenting with (stent&VBT group; 7 patients) or without (stent group; 7 patients) adjunctive beta-VBT. In-stent SS was calculated by applying computational fluid dynamics to the stent reconstruction and NT was determined in 3D space.
Results: NT was significantly increased in the stent group (0.2+/-0.16 mm vs. 0.07+/-0.18 mm, p<0.001). The estimated intercepts and slopes regarding the relationship of NT with SS were 0.28 mm [95% confidence interval (CI): 0.20 to 0.36 mm, p<0.001] and -0.057 mm/Pa (95% CI: -0.062 to -0.052 mm/Pa, p<0.001) respectively for the stent group, and 0.15 mm (95% CI: -0.02 to 0.31 mm, p=0.082) and -0.017 mm/Pa (95% CI: -0.023 to -0.010 mm/Pa, p<0.001) respectively for the stent&VBT group. After pooling all data together, a significant effect of VBT on the relationship between NT and SS was found [estimate of interaction term (groupxSS) for stent&VBT vs. stent group: 0.04 mm/Pa; 95% CI: 0.032 to 0.049 mm/Pa, p<0.001].
Conclusions: In-stent restenosis is inversely related to SS after coronary artery stenting and VBT diminishes the inverse relationship between NT and SS.
Similar articles
-
The effect of shear stress on neointimal response following sirolimus- and paclitaxel-eluting stent implantation compared with bare-metal stents in humans.JACC Cardiovasc Interv. 2010 Nov;3(11):1181-9. doi: 10.1016/j.jcin.2010.08.018. JACC Cardiovasc Interv. 2010. PMID: 21087755
-
Sirolimus-eluting stent implantation and beta-irradiation for the treatment of in-stent restenotic lesions: comparison of underlying mechanisms of acute gain and late loss as assessed by volumetric intravascular ultrasound.Am Heart J. 2005 Aug;150(2):351-7. doi: 10.1016/j.ahj.2004.09.041. Am Heart J. 2005. PMID: 16086942 Clinical Trial.
-
Additional stenting promotes intimal proliferation and compromises the results of intravascular radiation therapy: an intravascular ultrasound study.Am Heart J. 2003 Jul;146(1):142-5. doi: 10.1016/S0002-8703(03)00147-9. Am Heart J. 2003. PMID: 12851623 Clinical Trial.
-
Brachytherapy for restenosis after stenting for coronary artery disease: its role in the drug-eluting stent era.Curr Opin Cardiol. 2004 Nov;19(6):601-7. doi: 10.1097/01.hco.0000142069.39957.03. Curr Opin Cardiol. 2004. PMID: 15502506 Review.
-
Vascular changes and black hole phenomenon after coronary brachytherapy: a pathologically distinct entity.J Invasive Cardiol. 2008 Oct;20(10):560-2. J Invasive Cardiol. 2008. PMID: 18830004 Review.
Cited by
-
Fractional Flow Reserve following Percutaneous Coronary Intervention.J Interv Cardiol. 2020 Jun 5;2020:7467943. doi: 10.1155/2020/7467943. eCollection 2020. J Interv Cardiol. 2020. PMID: 32565755 Free PMC article. Review.
-
Application of physics-based flow models in cardiovascular medicine: Current practices and challenges.Biophys Rev (Melville). 2021 Mar 22;2(1):011302. doi: 10.1063/5.0040315. eCollection 2021 Mar. Biophys Rev (Melville). 2021. PMID: 38505399 Free PMC article. Review.
-
Focus on the research utility of intravascular ultrasound - comparison with other invasive modalities.Cardiovasc Ultrasound. 2011 Jan 30;9(1):2. doi: 10.1186/1476-7120-9-2. Cardiovasc Ultrasound. 2011. PMID: 21276268 Free PMC article. Review.
-
Simulation of atherosclerotic plaque growth using computational biomechanics and patient-specific data.Sci Rep. 2020 Oct 15;10(1):17409. doi: 10.1038/s41598-020-74583-y. Sci Rep. 2020. PMID: 33060746 Free PMC article.
-
Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived reconstructions.Int J Cardiovasc Imaging. 2014 Mar;30(3):485-94. doi: 10.1007/s10554-014-0374-3. Epub 2014 Jan 24. Int J Cardiovasc Imaging. 2014. PMID: 24458955
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials