LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the range of 20-250 kVp relative to 60Co
- PMID: 18561661
- DOI: 10.1118/1.2898137
LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the range of 20-250 kVp relative to 60Co
Abstract
The response of LiF:Mg,Ti thermoluminescent dosimeters (TLDs) as a function of photon energy was determined using irradiations with moderately filtered x-ray beams in the energy range of 20-250 kVp relative to the response to irradiations with 60Co photons. To determine if the relative light output from LiF:Mg,Ti TLDs per unit air kerma as a function of photon energy can be predicted using calculations such as Monte Carlo (MC) simulations, measurements from the x-ray beam irradiations were compared with MC calculated results, similar to the methodology used by Davis et al. [Radiat. Prot. Dosim. 106, 33-43 (2003)]. TLDs were irradiated in photon beams with well-known air kerma rates using the National Institute of Standards and Technology traceable M-series x-ray beams in the range of 20-250 kVp. For each x-ray beam, several sets of TLDs were irradiated for times corresponding to different air kerma levels to take into account any dose nonlinearity. TLD light output was then compared to that from several sets of TLDs irradiated at similar corresponding air kerma levels using a 60Co irradiator. The MC code MCNP5 was used to account for photon scatter and attenuation in the holder and TLDs and was used to calculate the predicted relative TLD light output per unit air kerma for irradiations with each of the experimentally used photon beams. The measured relative TLD response as a function of photon energy differed by up to 13% from the MC calculations. We conclude that MC calculations do not accurately predict the relative response of TLDs as a function of photon energy, consistent with the conclusions of Davis et al. [Radiat. Prot. Dosim. 106, 33-43 (2003)]. This is likely due to complications in the solid state physics of the thermoluminescence process that are not incorporated into the simulation.
Similar articles
-
Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).Med Phys. 2011 Oct;38(10):5539-50. doi: 10.1118/1.3633892. Med Phys. 2011. PMID: 21992372
-
Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co.Med Phys. 2014 Dec;41(12):122103. doi: 10.1118/1.4901300. Med Phys. 2014. PMID: 25471976
-
The response of lif thermoluminescence dosemeters to photon beams in the energy range from 30 kV x rays to 60Co gamma rays.Radiat Prot Dosimetry. 2003;106(1):33-43. doi: 10.1093/oxfordjournals.rpd.a006332. Radiat Prot Dosimetry. 2003. PMID: 14653324
-
The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.Radiat Prot Dosimetry. 2006;119(1-4):248-54. doi: 10.1093/rpd/nci692. Epub 2006 Jul 11. Radiat Prot Dosimetry. 2006. PMID: 16835277 Review.
-
The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P.Radiat Prot Dosimetry. 2004;109(4):331-48. doi: 10.1093/rpd/nch310. Radiat Prot Dosimetry. 2004. PMID: 15273352 Review.
Cited by
-
Absorbed dose and dose rate using the Varian OBI 1.3 and 1.4 CBCT system.J Appl Clin Med Phys. 2010 Jan 28;11(1):3085. doi: 10.1120/jacmp.v11i1.3085. J Appl Clin Med Phys. 2010. PMID: 20160695 Free PMC article.
-
A Mail Audit Independent Peer Review System for Dosimetry Verification of a Small Animal Irradiator.Radiat Res. 2020 Apr;193(4):341-350. doi: 10.1667/RR15220.1. Epub 2020 Feb 18. Radiat Res. 2020. PMID: 32068498 Free PMC article.
-
Exposure Time Dependence of Operators' Head Entrance Air Kerma in Interventional Radiology Measured by TLD-100H Chips.Sensors (Basel). 2025 Jun 11;25(12):3666. doi: 10.3390/s25123666. Sensors (Basel). 2025. PMID: 40573552 Free PMC article.
-
Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner.Med Phys. 2011 Apr;38(4):1919-30. doi: 10.1118/1.3560422. Med Phys. 2011. PMID: 21626925 Free PMC article.
-
New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design.J Contemp Brachytherapy. 2013 Dec;5(4):240-9. doi: 10.5114/jcb.2013.39631. Epub 2013 Dec 21. J Contemp Brachytherapy. 2013. PMID: 24474975 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources