Binding behavior of CRP and anti-CRP antibody analyzed with SPR and AFM measurement
- PMID: 18562112
- DOI: 10.1016/j.ultramic.2008.04.064
Binding behavior of CRP and anti-CRP antibody analyzed with SPR and AFM measurement
Abstract
Atomic force microscope (AFM) was exploited to take picture of the molecular topology of C-reactive protein (CRP) in phosphate-buffered saline (PBS) solution. An explicit molecular image of CRP demonstrated a pentagonal structure composed of five subunits. Dimensions of the doughnut-shaped CRP molecule measured by AFM were about 25 nm in outside diameter and 10 nm in central pore diameter, and the height of CRP molecule was about 4 nm which was comparable to the value determined by X-ray crystallography. Bis(N-succinimido)-11,11'-dithiobis (undecyl succinate) (DSNHS) was synthesized for use as a linker for immobilizing anti-CRP antibody (anti-CRP) onto the gold surface of a surface plasmon resonance (SPR) sensor chip. DSNHS formed self-assembled monolayer (SAM) on the gold surface. By use of an AFM tip, a pattern of ditch was engraved within the SAM of DSNHS, and anti-CRP was immobilized on the engraved SAM through replacement of N-hydroxysuccinimide group on the outside surface of DSNHS by the amine group of anti-CRP. Formation of CRP/anti-CRP complex on the gold surface of SPR sensor chip was clearly demonstrated by measuring SPR angle shift. A consecutive series of SAM, SAM/anti-CRP, and SAM/anti-CRP/CRP complexes was generated on a SPR sensor chip, and the changes in depth of the ditch were monitored by taking AFM images of the complexes. Comparative analysis of the depth differences indicates that binding of CRP to anti-CRP occurs in a planar mode.
Similar articles
-
Measurement of dimensions of pentagonal doughnut-shaped C-reactive protein using an atomic force microscope and a dual polarisation interferometric biosensor.Biosens Bioelectron. 2006 Aug 15;22(2):323-7. doi: 10.1016/j.bios.2006.01.018. Epub 2006 Feb 28. Biosens Bioelectron. 2006. PMID: 16510273
-
Detection of C-reactive protein on a functional poly(thiophene) self-assembled monolayer using surface plasmon resonance.Ultramicroscopy. 2008 Sep;108(10):1379-83. doi: 10.1016/j.ultramic.2008.04.052. Epub 2008 May 10. Ultramicroscopy. 2008. PMID: 18565665
-
Site-directed immobilisation of antibody fragments for detection of C-reactive protein.Biosens Bioelectron. 2006 Jan 15;21(7):1141-8. doi: 10.1016/j.bios.2005.04.011. Biosens Bioelectron. 2006. PMID: 15905085
-
Surface plasmon resonance biosensing.Methods Mol Biol. 2009;503:65-88. doi: 10.1007/978-1-60327-567-5_5. Methods Mol Biol. 2009. PMID: 19151937 Review.
-
Surface plasmon resonance and surface plasmon field-enhanced fluorescence spectroscopy for sensitive detection of tumor markers.Methods Mol Biol. 2009;503:3-20. doi: 10.1007/978-1-60327-567-5_1. Methods Mol Biol. 2009. PMID: 19151933 Review.
Cited by
-
Application of paper-supported printed gold electrodes for impedimetric immunosensor development.Biosensors (Basel). 2012 Dec 27;3(1):1-17. doi: 10.3390/bios3010001. eCollection 2013 Mar. Biosensors (Basel). 2012. PMID: 25587396 Free PMC article.
-
Kinetic analysis of antibody binding to integral membrane proteins stabilized in SMALPs.BBA Adv. 2021 Aug 5;1:100022. doi: 10.1016/j.bbadva.2021.100022. eCollection 2021. BBA Adv. 2021. PMID: 37082021 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous