Smart infusion technology: a minimum safety standard for intensive care?
- PMID: 18563002
- DOI: 10.12968/bjon.2008.17.10.29476
Smart infusion technology: a minimum safety standard for intensive care?
Abstract
There is overwhelming evidence that medication errors present a risk to patients. This risk is highest in the intensive care unit (ICU) setting and even greater when medications are administered via an infusion pump. Standard pumps will not alert for, or prevent, drug calculation, drug unit, button push, or multiple of ten errors when medication delivery data is inputted. However, the literature suggests that smart pumps programmed with hard (unchangeable) limits can significantly reduce drug errors at the point of administration. Staff at St George's Hospital paediatric ICU wanted to implement an infusion pump system that would be immediately effective in reducing medication errors at the point of administration. This article presents an overview of the relevant literature together with clinical examples from the authors' ICU, which demonstrates their experiences with smart pumps. It is the authors' firm belief that smart infusion technology sets a new minimum safety standard for intensive care.
Similar articles
-
Smart i.v. pumps.RN. 2005 Dec;68(12):38-43; quiz 44. RN. 2005. PMID: 16411553 Review. No abstract available.
-
Implementation of smart pump technology in a paediatric intensive care unit.Health Informatics J. 2015 Sep;21(3):209-22. doi: 10.1177/1460458213518058. Epub 2014 Feb 4. Health Informatics J. 2015. PMID: 24496443
-
Analyze this: smart pumps get an IQ boost.Nurs Manage. 2007 Dec;38(12):38-42. doi: 10.1097/01.NUMA.0000303870.03514.dc. Nurs Manage. 2007. PMID: 18182947 No abstract available.
-
Advancing medication infusion safety through the clinical integration of technology.Hosp Pract (1995). 2013 Oct-Nov;41(4):7-14. doi: 10.3810/hp.2013.10.1075. Hosp Pract (1995). 2013. PMID: 24145584
-
Intravenous Smart Pumps: Usability Issues, Intravenous Medication Administration Error, and Patient Safety.Crit Care Nurs Clin North Am. 2018 Jun;30(2):215-224. doi: 10.1016/j.cnc.2018.02.004. Epub 2018 Apr 7. Crit Care Nurs Clin North Am. 2018. PMID: 29724440 Review.
Cited by
-
Multiple Intravenous Infusions Phase 2b: Laboratory Study.Ont Health Technol Assess Ser. 2014 May 1;14(5):1-163. eCollection 2014. Ont Health Technol Assess Ser. 2014. PMID: 26316919 Free PMC article.
-
Quantifying the Impact of Infusion Alerts and Alarms on Nursing Workflows: A Retrospective Analysis.Appl Clin Inform. 2021 May;12(3):528-538. doi: 10.1055/s-0041-1730031. Epub 2021 Jun 30. Appl Clin Inform. 2021. PMID: 34192773 Free PMC article.
-
Achieving Outcomes With Innovative Smart Pump Technology: Partnership, Planning, and Quality Improvement.J Nurs Care Qual. 2019 Jan/Mar;34(1):9-15. doi: 10.1097/NCQ.0000000000000326. J Nurs Care Qual. 2019. PMID: 29634499 Free PMC article.
-
Exploring the Current Landscape of Intravenous Infusion Practices and Errors (ECLIPSE): protocol for a mixed-methods observational study.BMJ Open. 2016 Mar 3;6(3):e009777. doi: 10.1136/bmjopen-2015-009777. BMJ Open. 2016. PMID: 26940104 Free PMC article.
-
The impact of traditional and smart pump infusion technology on nurse medication administration performance in a simulated inpatient unit.Qual Saf Health Care. 2010 Oct;19(5):430-4. doi: 10.1136/qshc.2009.032839. Epub 2010 Apr 27. Qual Saf Health Care. 2010. PMID: 20427310 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical