Abstract
We administer anesthetics to obtain therapeutic effects and minimize untoward side effects. Anesthetists can precisely control inhaled anesthetic concentrations by controlling end-tidal volatile anesthetic concentrations. This degree of control eliminates the need for closed-loop inhaled anesthetic systems. The low solubility of modern inhaled anesthetics adds to the stability and control of the anesthetic state; the effective inhaled concentration varies little during maintenance of anesthesia unless altered by the anesthetist. A less precise closed-loop system applies a processed electroencephalogram (EEG) to assess depth of anesthesia and enable accurate delivery of volatile and intravenous anesthetics to maintain a stable state of anesthesia.
Similar articles
-
Advanced technologies and devices for inhalational anesthetic drug dosing.Handb Exp Pharmacol. 2008;(182):451-70. doi: 10.1007/978-3-540-74806-9_21. Handb Exp Pharmacol. 2008. PMID: 18175104 Review.
-
Automatic control of anesthetic delivery and ventilation during surgery.Med Prog Technol. 1990 May;16(1-2):61-7. Med Prog Technol. 1990. PMID: 2138698 Clinical Trial.
-
Special aspects of pharmacokinetics of inhalation anesthesia.Handb Exp Pharmacol. 2008;(182):159-86. doi: 10.1007/978-3-540-74806-9_8. Handb Exp Pharmacol. 2008. PMID: 18175091 Review.
-
Clinical applications of low flow and closed circuit anesthesia.Acta Anaesthesiol Belg. 1990;41(3):239-47. Acta Anaesthesiol Belg. 1990. PMID: 2260429
-
Brief review: theory and practice of minimal fresh gas flow anesthesia.Can J Anaesth. 2012 Aug;59(8):785-97. doi: 10.1007/s12630-012-9736-2. Epub 2012 Jun 1. Can J Anaesth. 2012. PMID: 22653840 Review.
Cited by
-
Optimizing target control of the vessel rich group with volatile anesthetics.J Clin Monit Comput. 2019 Jun;33(3):445-454. doi: 10.1007/s10877-018-0169-5. Epub 2018 Jun 21. J Clin Monit Comput. 2019. PMID: 29931573 Free PMC article.
-
Comparative study of a modified double-lumen tube ventilation control connector and traditional connector in clinical use: a randomised-controlled trial.BMC Anesthesiol. 2022 Sep 6;22(1):281. doi: 10.1186/s12871-022-01816-0. BMC Anesthesiol. 2022. PMID: 36068501 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources