Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Jun;31(6):805-13.
doi: 10.1007/s12272-001-1230-5. Epub 2008 Jun 19.

Simultaneous determination of amphetamine-type stimulants and cannabinoids in fingernails by gas chromatography-mass spectrometry

Affiliations

Simultaneous determination of amphetamine-type stimulants and cannabinoids in fingernails by gas chromatography-mass spectrometry

Jin Young Kim et al. Arch Pharm Res. 2008 Jun.

Abstract

A gas chromatography-mass spectrometric (GC-MS) method was developed and validated for the simultaneous detection and quantification of four amphetamine-type stimulants (amphetamine (AP), methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxymethamphetamine (MDMA)) and two cannabinoids (Delta9-tetrahydrocannabinol (Delta9-THC) and 11-nor-Delta9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH)) in fingernails. Fingernail clippings (30 mg) were washed with distilled water and methanol, and then incubated in 1.0 M sodium hydroxide at 95 degrees C for 30 min. The compounds of interest were isolated by liquid-liquid extraction followed by derivatization with N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA) at 70 degrees C for 15 min. The derivatized compounds were analyzed by GC-MS in the selective ion monitoring (SIM) mode. The linear ranges were 0.1-15.0 ng/mg for AP, 0.2-15.0 ng/mg for MDA, Delta9-THC and THCCOOH, and 0.2-30.0 ng/mg for MA and MDMA, with good correlation coefficients (r2 > 0.9991). The intra-day, inter-day, and inter-person precisions were within 10.6%, 6.3%, and 5.3%, respectively. The intra-day, inter-day and inter-person accuracies were between -6.1 and 5.0%, -6.2 and 5.7%, and -6.4 and 5.6%, respectively. The limits of detection (LODs) and quantification (LOQs) for each compound were lower than 0.056 and 0.2 ng/mg, respectively. The recoveries were in the range of 74.0-94.8%. Positive GC-MS results were obtained from specimens of nine suspected MA or cannabis abusers. The concentration ranges of MA, AP, and THCCOOH were 0.10-1.41, 0.12-2.64, and 0.20 ng/mg, respectively. Based on these results, the method proved to be effective for the simultaneous qualification and quantification of amphetamine-type stimulants and cannabinoids in fingernails.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources