Controlled delivery of paclitaxel from stent coatings using novel styrene maleic anhydride copolymer formulations
- PMID: 18563805
- DOI: 10.1002/jbm.a.31969
Controlled delivery of paclitaxel from stent coatings using novel styrene maleic anhydride copolymer formulations
Abstract
The controlled release of paclitaxel (PTx) from stent coatings comprising an elastomeric polymer blended with a styrene maleic anhydride (SMA) copolymer is described. The coated stents were characterized for morphology by scanning electron microscopy (SEM) and atomic force microscopy (AFM), and for drug release using high-performance liquid chromatography (HPLC). Differential scanning calorimetry (DSC) was used to measure the extent of interaction between the PTx and polymers in the formulation. Coronary stents were coated with blends of poly(b-styrene-b-isobutylene-b-styrene) (SIBS) and SMA containing 7% or 14% maleic anhydride (MA) by weight. SEM examination of the stents showed that the coating did not crack or delaminate either before or after stent expansion. Examination of the coating surface via AFM after elution of the drug indicated that PTx resides primarily in the SMA phase and provided information about the mechanism of PTx release. The addition of SMA altered the release profile of PTx from the base elastomer coatings. In addition, the presence of the SMA enabled tunable release of PTx from the elastomeric stent coatings, while preserving mechanical properties. Thermal analysis reveled no shift in the glass transition temperatures for any of the polymers at all drug loadings studied, indicating that the PTx is not miscible with any component of the polymer blend. An in vivo evaluation indicated that biocompatibility and vascular response results for SMA/SIBS-coated stents (without PTx) are similar to results for SIBS-only-coated and bare stainless steel control stents when implanted in the non-injured coronary arteries of common swine for 30 and 90 days.
Similar articles
-
Controlled delivery of paclitaxel from stent coatings using poly(hydroxystyrene-b-isobutylene-b-hydroxystyrene) and its acetylated derivative.Biomacromolecules. 2005 Sep-Oct;6(5):2570-82. doi: 10.1021/bm050299j. Biomacromolecules. 2005. PMID: 16153094
-
Physical characterization of controlled release of paclitaxel from the TAXUS Express2 drug-eluting stent.J Biomed Mater Res A. 2004 Dec 15;71(4):625-34. doi: 10.1002/jbm.a.30188. J Biomed Mater Res A. 2004. PMID: 15514926
-
Evaluation of acrylate-based block copolymers prepared by atom transfer radical polymerization as matrices for paclitaxel delivery from coronary stents.Biomacromolecules. 2005 Nov-Dec;6(6):3410-8. doi: 10.1021/bm050464v. Biomacromolecules. 2005. PMID: 16283773
-
Drug-eluting stent coatings.Wiley Interdiscip Rev Nanomed Nanobiotechnol. 2009 Jul-Aug;1(4):451-62. doi: 10.1002/wnan.38. Wiley Interdiscip Rev Nanomed Nanobiotechnol. 2009. PMID: 20049810 Review.
-
Medical applications of poly(styrene-block-isobutylene-block-styrene) ("SIBS").Biomaterials. 2008 Feb;29(4):448-60. doi: 10.1016/j.biomaterials.2007.09.041. Epub 2007 Nov 5. Biomaterials. 2008. PMID: 17980425 Review.
Cited by
-
Influence of unsaturated carbonic acids on hemocompatibility and cytotoxicity of poly-vinylacetate based co-polymers.J Mater Sci Mater Med. 2010 May;21(5):1693-702. doi: 10.1007/s10856-010-4020-x. Epub 2010 Feb 17. J Mater Sci Mater Med. 2010. PMID: 20162328
-
Bioderived copolymer alternatives to poly(styrene-co-maleic anhydride) via RAFT-mediated copolymerization.Polym Chem. 2025 Jan 17;16(9):1019-1023. doi: 10.1039/d4py01227e. eCollection 2025 Feb 25. Polym Chem. 2025. PMID: 39831173 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous