Introduction of HPLC/orbitrap mass spectrometry as screening method for doping control
- PMID: 18563856
- DOI: 10.1002/jms.1447
Introduction of HPLC/orbitrap mass spectrometry as screening method for doping control
Abstract
A new doping control screening method has been developed, for the analysis of doping agents in human urine, using HPLC/orbitrap with in-source collision-induced dissociation and atmospheric pressure chemical ionization. The developed method allows the detection of 29 compounds, including agents with antiestrogenic activity, beta(2) agonists, exogenous anabolic steroids, and other anabolic agents. The mass accuracy of this method is better at 2 ppm using an external reference. The detection limit for all compounds tested was better than 100 pg/ml. The recoveries of most analytes were above 70%. The measured median repeatability values for doping agents included in the method at concentrations of 1 and 10 ng/ml were 21 and 17%, respectively. The relative standard deviation (RSD) of the intraday precision (n = 6) ranged from RSD = 16-22%, whereas the interday precision (n = 18), ranged from RSD = 17-26%, depending on the solute concentration investigated.
Copyright 2008 John Wiley & Sons, Ltd.
Similar articles
-
A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometry.Anal Chim Acta. 2007 Feb 28;585(1):94-102. doi: 10.1016/j.aca.2006.12.028. Epub 2006 Dec 23. Anal Chim Acta. 2007. PMID: 17386652
-
Validation and application of a screening method for beta2-agonists, anti-estrogenic substances and mesocarb in human urine using liquid chromatography/tandem mass spectrometry.Rapid Commun Mass Spectrom. 2007;21(2):252-64. doi: 10.1002/rcm.2834. Rapid Commun Mass Spectrom. 2007. PMID: 17171780
-
Doping control analysis of tricyclic tetrahydroquinoline-derived selective androgen receptor modulators using liquid chromatography/electrospray ionization tandem mass spectrometry.Rapid Commun Mass Spectrom. 2008 Aug;22(16):2471-8. doi: 10.1002/rcm.3637. Rapid Commun Mass Spectrom. 2008. PMID: 18634123
-
Mass spectrometry of selective androgen receptor modulators.J Mass Spectrom. 2008 Jul;43(7):865-76. doi: 10.1002/jms.1438. J Mass Spectrom. 2008. PMID: 18521833 Review.
-
Mass spectrometry in sports drug testing: Structure characterization and analytical assays.Mass Spectrom Rev. 2007 Jan-Feb;26(1):79-107. doi: 10.1002/mas.20107. Mass Spectrom Rev. 2007. PMID: 16888758 Review.
Cited by
-
Full-scan accurate mass selectivity of ultra-performance liquid chromatography combined with time-of-flight and orbitrap mass spectrometry in hormone and veterinary drug residue analysis.J Am Soc Mass Spectrom. 2009 Mar;20(3):451-63. doi: 10.1016/j.jasms.2008.11.002. Epub 2008 Nov 17. J Am Soc Mass Spectrom. 2009. PMID: 19101163
-
Fast and Sensitive Screening of Oxandrolone and Its Major Metabolite 17-Epi-Oxandrolone in Human Urine by UHPLC-MS/MS with On-Line SPE Sample Pretreatment.Molecules. 2021 Jan 18;26(2):480. doi: 10.3390/molecules26020480. Molecules. 2021. PMID: 33477515 Free PMC article.
-
Generic sample preparation combined with high-resolution liquid chromatography-time-of-flight mass spectrometry for unification of urine screening in doping-control laboratories.Anal Bioanal Chem. 2010 Apr;396(7):2583-98. doi: 10.1007/s00216-010-3484-3. Epub 2010 Feb 16. Anal Bioanal Chem. 2010. PMID: 20155493 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical