Comparison of the laryngeal mask (LMA) and laryngeal tube (LT) with the perilaryngeal airway (cobraPLA) in brief paediatric surgical procedures
- PMID: 18564805
- DOI: 10.1177/0310057X0803600314
Comparison of the laryngeal mask (LMA) and laryngeal tube (LT) with the perilaryngeal airway (cobraPLA) in brief paediatric surgical procedures
Abstract
We compared the laryngeal mask airway (LMA) and the laryngeal tube (LT) with the perilaryngeal airway (CobraPLA, PLA) in anaesthetised, paralysed children having brief surgical procedures. After obtaining informed consent, 90 paediatric ASA Status 1 and 2 patients awaiting short surgical procedures were randomised to have their airways managed with an LMA, LT or PLA. Anaesthesia was induced with sevoflurane (2.5 to 4%) and muscle paralysis with mivacurium (0.2 mg/kg intravenously). The number of insertion attempts, time taken to insert the device, haemodynamic responses to insertion (mean arterial blood pressure, heart rate, pulse oximetry and end-tidal CO2), clinical performance and occurrence of postoperative sore throat were recorded. When the airway device was removed, it was examined for visible blood. Patients and parents were asked about the occurrence of sore throat, dysphonia and dysphagia 24 hours postoperatively. Heart rate, mean arterial blood pressure, pulse oximetry and end tidal CO2 did not differ among the groups. Insertion times for the devices were similar (LMA: 19+/-11 seconds, LT 21+/-12 seconds, PLA: 18+/-12 seconds), as were the rates of successful insertion at first attempt (LMA 66.7%; LT 70.0%; PLA 73.3%). The number and type of airway interventions to achieve an effective airway were comparable. When the airways were removed, positive blood traces were noted on 20% of the LMAs, 20% of the PLAs and 10% of the LTs. Haemodynamic, ventilation and oxygenation variables throughout the surgery were similar with LMA, LT and PLA and there were no significant differences in insertion time or signs or symptoms of mucosal trauma when these devices were used in paralysed children.
Similar articles
-
Comparison of the laryngeal mask (LMA) and laryngeal tube (LT) with the new perilaryngeal airway (CobraPLA) in short surgical procedures.Eur J Anaesthesiol. 2006 Mar;23(3):234-8. doi: 10.1017/S0265021505002243. Eur J Anaesthesiol. 2006. PMID: 16430795 Clinical Trial.
-
Comparison of the VBM laryngeal tube and laryngeal mask airway for ventilation during manual in-line neck stabilisation.Singapore Med J. 2006 Oct;47(10):892-6. Singapore Med J. 2006. PMID: 16990966 Clinical Trial.
-
A comparison of the laryngeal tube with the laryngeal mask airway during routine surgical procedures.Anesth Analg. 2002 Oct;95(4):1094-7, table of contents. doi: 10.1097/00000539-200210000-00057. Anesth Analg. 2002. PMID: 12351302 Clinical Trial.
-
Brief review: the Cobra Perilaryngeal Airway (CobraPLA and the Streamlined Liner of Pharyngeal Airway (SLIPA) supraglottic airways.Can J Anaesth. 2008 Mar;55(3):177-85. doi: 10.1007/BF03016093. Can J Anaesth. 2008. PMID: 18310629 Review.
-
[The laryngeal tube].Rev Esp Anestesiol Reanim. 2008 Apr;55(4):232-41. doi: 10.1016/s0034-9356(08)70554-1. Rev Esp Anestesiol Reanim. 2008. PMID: 18543506 Review. Spanish.
Cited by
-
[Interdisciplinary consensus statement on alternative airway management with supraglottic airway devices in pediatric emergency medicine: Laryngeal mask is state of the art].Anaesthesist. 2016 Jan;65(1):57-66. doi: 10.1007/s00101-015-0107-6. Anaesthesist. 2016. PMID: 26661389 Review. German.
-
Laryngeal mask airway vs the endotracheal tube in paediatric airway management: A meta-analysis of prospective randomised controlled trials.Indian J Anaesth. 2011 Sep;55(5):537-41. doi: 10.4103/0019-5049.89900. Indian J Anaesth. 2011. PMID: 22174478 Free PMC article.
-
Comparing the Laryngeal Mask Airway, Cobra Perilaryngeal Airway and Face Mask in Children Airway Management.Turk J Anaesthesiol Reanim. 2016 Apr;44(2):81-5. doi: 10.5152/TJAR.2016.19970. Epub 2016 Apr 1. Turk J Anaesthesiol Reanim. 2016. PMID: 27366563 Free PMC article.
-
[Update 2022: interdisciplinary statement on airway management with supraglottic airway devices in pediatric emergency medicine-The laryngeal mask is and remains state of the art : Joint statement of the Institute for Emergency Medicine and Medicine Management (INM), the University Clinic Munich, LMU Munich, Germany, the Working Group for Pediatric Critical Care and Emergency Medicine of the German Interdisciplinary Society for Critical Care and Emergency Medicine (DIVI), the Medical Directors of Emergency Medical Services in Bavaria (ÄLRD), the Scientific Working Group for Pediatric Anesthesia (WAKKA) of the German Society for Anesthesiology and Intensive Care Medicine (DGAI), the Scientific Working Group for Emergency Medicine of the German Society for Anesthesiology and Intensive Care Medicine (DGAI) and the Society of Neonatology and Pediatric Critical Care Medicine (GNPI)].Anaesthesiologie. 2023 Jun;72(6):425-432. doi: 10.1007/s00101-023-01284-2. Epub 2023 May 24. Anaesthesiologie. 2023. PMID: 37222766 Review. German.
-