Theoretical analysis of the accuracy of calibrated immunoassays for measuring antibody concentration
- PMID: 1857350
- DOI: 10.1016/0161-5890(91)90115-z
Theoretical analysis of the accuracy of calibrated immunoassays for measuring antibody concentration
Abstract
The accuracy of calibrated immunoassays for measuring antibody concentration was analysed from a theoretical perspective. The study shows that there are theoretical limits on the accuracy of antibody immunoassays, which are determined by the affinity of the standard and unknown antibodies and the conditions chosen for the assay. As a result of these limits, calibration of an immunoassay with a standard antibody does not automatically ensure accurate measurements of antibody concentration. Extremely large errors may develop in affinity-dependent assays when the affinities of the standard and unknown antibodies are different. Assay conditions and the affinity of the standardizing antibody must be chosen carefully to measure antibody concentration accurately.
Similar articles
-
The importance of antibody affinity in the performance of immunoassays for antibody.J Immunol Methods. 1985 Apr 22;78(2):173-90. doi: 10.1016/0022-1759(85)90074-2. J Immunol Methods. 1985. PMID: 2580911 No abstract available.
-
The effect of variance function estimation on nonlinear calibration inference in immunoassay data.Biometrics. 1996 Mar;52(1):158-75. Biometrics. 1996. PMID: 8934590
-
Validation of immunoassays for bioanalysis: a pharmaceutical industry perspective.J Pharm Biomed Anal. 2000 Jan;21(6):1249-73. doi: 10.1016/s0731-7085(99)00244-7. J Pharm Biomed Anal. 2000. PMID: 10708409
-
The immunoassay of cytokines and growth factors in biological fluids.Dev Biol Stand. 1999;97:29-37. Dev Biol Stand. 1999. PMID: 10463528 Review.
-
Recommendations for the design, optimization, and qualification of cell-based assays used for the detection of neutralizing antibody responses elicited to biological therapeutics.J Immunol Methods. 2007 Apr 10;321(1-2):1-18. doi: 10.1016/j.jim.2006.12.004. Epub 2007 Jan 12. J Immunol Methods. 2007. PMID: 17307199 Review.
Cited by
-
Quantification of SARS-CoV-2 monoclonal IgG mass fraction by isotope dilution mass spectrometry.Anal Bioanal Chem. 2024 Apr;416(10):2423-2437. doi: 10.1007/s00216-024-05205-z. Epub 2024 Mar 1. Anal Bioanal Chem. 2024. PMID: 38427100
-
Assignment of weight-based antibody units to a human antipneumococcal standard reference serum, lot 89-S.Clin Diagn Lab Immunol. 1995 Sep;2(5):590-7. doi: 10.1128/cdli.2.5.590-597.1995. Clin Diagn Lab Immunol. 1995. PMID: 8548539 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Research Materials