High-field head radiofrequency volume coils using transverse electromagnetic (TEM) and phased array technologies
- PMID: 18574792
- DOI: 10.1002/nbm.1262
High-field head radiofrequency volume coils using transverse electromagnetic (TEM) and phased array technologies
Abstract
This article describes technological advances in quadrature transverse electromagnetic (TEM) volume coils and phased arrays reported recently from our laboratory developed for MRI and MRS imaging of the human brain. The first part of this work presents a new method for tuning TEM volume coils based on measurements of the radiofrequency current distribution in the coil elements. This technique facilitates bench adjustment of the coils' homogeneity and is particularly important for tuning double-tuned TEM volume coils. We have also used this method to optimize other TEM configurations such as a quadrature TEM half-volume coil and a split TEM coil. TEM half-volume coils provide greater sensitivity over localized regions than conventional full-volume coils, and the split TEM coil provides greater patient access and ease of use. The second part of this work describes the development of single-tuned and double-tuned transmit TEM volume coils in combination with phased arrays. A variety of different techniques for active detuning of single-tuned and double-tuned TEM volume coils are presented along with the development of phased arrays and transmission line preamplifier decoupling. The final section describes the use of counter rotating current (CRC) surface coils in phased arrays. Because of the intrinsic isolation of CRC coils from transmit volume coils, CRC arrays can be used simultaneously with volume coils for both reception and transmission. Near the center of the human head where both the phased array and the volume coil produce similar sensitivities, simultaneous reception enhances the signal-to-noise ratio. Conversely, simultaneous transmission can be used to boost the transmit field in peripheral brain regions from the volume coil to provide a more homogeneous transmit field.
Similar articles
-
Improved homogeneity of the transmit field by simultaneous transmission with phased array and volume coil.J Magn Reson Imaging. 2010 Aug;32(2):476-81. doi: 10.1002/jmri.22257. J Magn Reson Imaging. 2010. PMID: 20677280 Free PMC article.
-
SENSE imaging with a quadrature half-volume transverse electromagnetic (TEM) coil at 4T.J Magn Reson Imaging. 2006 Oct;24(4):934-8. doi: 10.1002/jmri.20714. J Magn Reson Imaging. 2006. PMID: 16958065
-
B1 field, SAR, and SNR comparisons for birdcage, TEM, and microstrip coils at 7T.J Magn Reson Imaging. 2006 Aug;24(2):439-43. doi: 10.1002/jmri.20635. J Magn Reson Imaging. 2006. PMID: 16786582
-
Radiofrequency microcoils for magnetic resonance imaging and spectroscopy.J Magn Reson. 2013 Apr;229:55-66. doi: 10.1016/j.jmr.2012.10.004. Epub 2012 Oct 26. J Magn Reson. 2013. PMID: 23142002 Review.
-
Theory and application of array coils in MR spectroscopy.NMR Biomed. 1997 Dec;10(8):394-410. doi: 10.1002/(sici)1099-1492(199712)10:8<394::aid-nbm494>3.0.co;2-0. NMR Biomed. 1997. PMID: 9542737 Review.
Cited by
-
Ultra-high-field RF coil development for evaluating upper extremity imaging applications.NMR Biomed. 2016 Dec;29(12):1768-1779. doi: 10.1002/nbm.3582. Epub 2016 Nov 3. NMR Biomed. 2016. PMID: 27809383 Free PMC article.
-
Improved homogeneity of the transmit field by simultaneous transmission with phased array and volume coil.J Magn Reson Imaging. 2010 Aug;32(2):476-81. doi: 10.1002/jmri.22257. J Magn Reson Imaging. 2010. PMID: 20677280 Free PMC article.
-
Clinical field-strength MRI of amyloid plaques induced by low-level cholesterol feeding in rabbits.Brain. 2009 May;132(Pt 5):1346-54. doi: 10.1093/brain/awp031. Epub 2009 Mar 17. Brain. 2009. PMID: 19293239 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical