Detection of Escherichia coli O157:H7, Salmonella typhimurium, and Legionella pneumophila in water using a flow-through chemiluminescence microarray readout system
- PMID: 18578502
- DOI: 10.1021/ac800318b
Detection of Escherichia coli O157:H7, Salmonella typhimurium, and Legionella pneumophila in water using a flow-through chemiluminescence microarray readout system
Abstract
Fast, sensitive, and especially, multianalyte test systems are currently of high interest for the monitoring and quality control of drinking water, since traditional microbiological methods are labor intensive and can take days until a response is achieved. In this study, the first flow-through chemiluminescence microarray was developed and characterized for the rapid and simultaneous detection of Escherichia coli O157:H7, Salmonella typhimurium, and Legionella pneumophila in water samples using a semiautomated readout system. Therefore, antibody microarrays were produced on poly(ethylene glycol)-modified glass substrates by means of a contact arrayer. For capturing bacteria, species-specific polyclonal antibodies were used. Cell recognition was carried out by binding of species-specific biotinylated antibodies. Chemiluminescence detection was accomplished by a streptavidin-horseradish peroxidase (HRP) catalyzed reaction of luminol and hydrogen peroxide. The chemiluminescence reaction that occurred was recorded by a sensitive charge-coupled device (CCD) camera. The overall assay time was 13 min, enabling a fast sample analysis. In multianalyte experiments, the detection limits were 3 x 10(6), 1 x 10(5), and 3 x 10(3) cells/mL for S. typhimurium, L. pneumophila, and E. coli O157:H7, respectively. Quantification of samples was possible in a wide concentration range with good recoveries. The presented system is well suited for quick and automatic water analysis.
Similar articles
-
Sensitive quantification of Escherichia coli O157:H7, Salmonella enterica , and Campylobacter jejuni by combining stopped polymerase chain reaction with chemiluminescence flow-through DNA microarray analysis.Anal Chem. 2011 Apr 15;83(8):3153-60. doi: 10.1021/ac2002214. Epub 2011 Mar 21. Anal Chem. 2011. PMID: 21417213
-
Development of a multichannel flow-through chemiluminescence microarray chip for parallel calibration and detection of pathogenic bacteria.Anal Bioanal Chem. 2009 Nov;395(6):1623-30. doi: 10.1007/s00216-009-2905-7. Epub 2009 Jul 3. Anal Bioanal Chem. 2009. PMID: 19575190
-
A rapid multiplexed chemiluminescent immunoassay for the detection of Escherichia coli O157:H7, Yersinia enterocolitica, Salmonella typhimurium, and Listeria monocytogenes pathogen bacteria.J Agric Food Chem. 2007 Jun 27;55(13):4933-9. doi: 10.1021/jf063600b. Epub 2007 May 26. J Agric Food Chem. 2007. PMID: 17530767
-
Simultaneous detection of Escherichia coli O157:H7 and Salmonella Typhimurium using quantum dots as fluorescence labels.Analyst. 2006 Mar;131(3):394-401. doi: 10.1039/b510888h. Epub 2005 Dec 7. Analyst. 2006. PMID: 16496048
-
[Chemiluminescent assay for biological substances--chemiluminescent assay for alkaline phosphatase using lucigenin and its application to enzyme immunoassay].Rinsho Byori. 2004 Oct;52(10):851-9. Rinsho Byori. 2004. PMID: 15624502 Review. Japanese.
Cited by
-
Recent developments in waterborne pathogen detection technologies.Environ Monit Assess. 2025 Feb 4;197(3):233. doi: 10.1007/s10661-025-13644-z. Environ Monit Assess. 2025. PMID: 39903332 Free PMC article. Review.
-
Microfluidic approaches for isolation, detection, and characterization of extracellular vesicles: Current status and future directions.Biosens Bioelectron. 2017 May 15;91:588-605. doi: 10.1016/j.bios.2016.12.062. Epub 2016 Dec 30. Biosens Bioelectron. 2017. PMID: 28088752 Free PMC article. Review.
-
Micro and Nano-Scale Technologies for Cell Mechanics.Nanobiomedicine (Rij). 2014 Jan 1;1:5. doi: 10.5772/59379. eCollection 2014 Jan-Dec. Nanobiomedicine (Rij). 2014. PMID: 30023016 Free PMC article. Review.
-
An aptamer-based biosensor for colorimetric detection of Escherichia coli O157:H7.PLoS One. 2012;7(11):e48999. doi: 10.1371/journal.pone.0048999. Epub 2012 Nov 7. PLoS One. 2012. PMID: 23145045 Free PMC article.
-
Capture efficiency of Escherichia coli in fimbriae-mediated immunoimmobilization.Langmuir. 2012 Jan 17;28(2):1351-9. doi: 10.1021/la203348j. Epub 2011 Dec 28. Langmuir. 2012. PMID: 22149536 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources