Measurement of urinary free cortisol by tandem mass spectrometry and comparison with results obtained by gas chromatography-mass spectrometry and two commercial immunoassays
- PMID: 18583623
- DOI: 10.1258/acb.2007.007119
Measurement of urinary free cortisol by tandem mass spectrometry and comparison with results obtained by gas chromatography-mass spectrometry and two commercial immunoassays
Abstract
Background: Determination of urinary free cortisol (UFC) is an important adjunct for the assessment of adrenal function. In this study, we have analysed cortisol concentrations in urine samples by gas chromatography-mass spectrometry (GC-MS), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and two immunoassays. The results were compared with GC-MS. The interference of cortisol ring-A metabolites in immunoassays was also assessed.
Methods: The GC-MS technique involved solvent extraction, LH-20 clean-up and derivatization. Only solid-phase extraction procedure was used for LC-MS/MS. The samples were analysed in positive electro-spray ionization mode, monitoring the transitions for cortisol and deuterated-cortisol at m/z 363.3 > 121.2 and m/z 365.3 > 122.2, respectively. Immunoassays were performed according to the manufacturer's instructions.
Results: When compared with GC-MS results both immunoassays (Coat-A-Count; approximately 1.9-fold, Centaur; approximately 1.6-fold) overestimated UFC concentrations. Cortisol ring-A dihydro- and tetrahydrometabolites contribute significantly to this overestimation. There was no interference by these metabolites in either GC-MS or LC-MS/MS methods. The sensitivity of the LC-MS/MS procedure was 2 nmol/L and the intra- and inter-assay variations were <5% in each quality-control sample. The comparison of the UFC results achieved by assaying the study samples with GC-MS and LC-MS/MS indicated that the agreement between the two methods was excellent (LC-MS/MS = 1.0036GC-MS - 0.0841; r2 = 0.9937).
Conclusions: The interference of cortisol ring-A metabolites in immunoassays contribute to overestimation of UFC concentrations. The LC-MS/MS procedure had the sensitivity, specificity, linearity, precision and accuracy for the determination of UFC concentrations. The method is suitable for routine use provided that method-dependant reference values are established.
Similar articles
-
Measurement of urinary free cortisol using liquid chromatography-tandem mass spectrometry: comparison with the urine adapted ACS:180 serum cortisol chemiluminescent immunoassay and development of a new reference range.Ann Clin Biochem. 2005 Mar;42(Pt 2):112-8. doi: 10.1258/0004563053492775. Ann Clin Biochem. 2005. PMID: 15829119
-
Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.Anal Chem. 2004 Feb 15;76(4):1008-14. doi: 10.1021/ac034966f. Anal Chem. 2004. PMID: 14961732
-
A simplified liquid chromatography tandem mass spectrometry assay, using on-line solid-phase extraction, for the quantitation of cortisol in saliva and comparison with a routine DELFIA method.Ann Clin Biochem. 2010 Mar;47(Pt 2):131-6. doi: 10.1258/acb.2009.009053. Epub 2010 Feb 11. Ann Clin Biochem. 2010. PMID: 20150214
-
Liquid chromatography tandem-mass spectrometry (LC-MS/MS)--technique and applications in endocrinology.Exp Clin Endocrinol Diabetes. 2007 Oct;115(9):559-70. doi: 10.1055/s-2007-981458. Exp Clin Endocrinol Diabetes. 2007. PMID: 17943689 Review.
-
Measurement of oxidative stress parameters using liquid chromatography-tandem mass spectroscopy (LC-MS/MS).Toxicol Appl Pharmacol. 2008 Nov 15;233(1):100-6. doi: 10.1016/j.taap.2008.05.003. Epub 2008 May 9. Toxicol Appl Pharmacol. 2008. PMID: 18547599 Review.
Cited by
-
Acute Valproate Exposure Induces Sex-Specific Changes in Steroid Hormone Metabolism in the Cerebral Cortex of Juvenile Mice.Neurochem Res. 2020 Sep;45(9):2044-2051. doi: 10.1007/s11064-020-03065-4. Epub 2020 Jun 29. Neurochem Res. 2020. PMID: 32601984
-
Quantification of cortisol and its metabolites in human urine by LC-MSn: applications in clinical diagnosis and anti-doping control.Anal Bioanal Chem. 2022 Sep;414(23):6841-6853. doi: 10.1007/s00216-022-04249-3. Epub 2022 Aug 2. Anal Bioanal Chem. 2022. PMID: 35915250 Free PMC article.
-
Portable Chemiluminescence-Based Lateral Flow Assay Platform for the Detection of Cortisol in Human Serum.Biosensors (Basel). 2021 Jun 10;11(6):191. doi: 10.3390/bios11060191. Biosensors (Basel). 2021. PMID: 34200643 Free PMC article.
-
Metabolic profiling of cholesterol and sex steroid hormones to monitor urological diseases.Endocr Relat Cancer. 2016 Oct;23(10):R455-67. doi: 10.1530/ERC-16-0285. Endocr Relat Cancer. 2016. PMID: 27580660 Free PMC article. Review.
-
Variability in laboratory parameters used for management of Cushing's syndrome.Endocrine. 2015 Dec;50(3):580-9. doi: 10.1007/s12020-015-0676-9. Epub 2015 Jul 10. Endocrine. 2015. PMID: 26160393 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous