Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2008 May;25(5):453-64.
doi: 10.1007/s12325-008-0062-6.

Coexistent primary open-angle glaucoma and cataract: preliminary analysis of treatment by cataract surgery and the iStent trabecular micro-bypass stent

Affiliations
Multicenter Study

Coexistent primary open-angle glaucoma and cataract: preliminary analysis of treatment by cataract surgery and the iStent trabecular micro-bypass stent

Detlev Spiegel et al. Adv Ther. 2008 May.

Abstract

Introduction: Reducing intraocular pressure (IOP) is the only proven treatment modality for reducing the risk of glaucomatous progression. In this study, we evaluated the safety and efficacy of a new tool in IOP reduction, implanted with cataract surgery: the Glaukos iStent trabecular micro-bypass stent.

Methods: This was a prospective, 24-month, uncontrolled, non-randomised, multicentre study. Subjects with uncontrolled primary open-angle glaucoma (including pseudoexfoliation and pigmentary) and a cataract underwent clear cornea phacoemulsification cataract extraction with ab-interno gonioscopically guided implantation of the study stent. Subjects who had completed at least 6 months of follow-up were included in this interim analysis (n=47).

Results: At baseline, mean (+/-standard deviation) IOP was 21.5+/-3.7 mmHg, and subjects were taking a mean of 1.5+/-0.7 ocular hypotensive medications. Six months after implantation of the study stent the mean IOP was 15.8+/- 3.0 mmHg, a mean IOP reduction of 5.7+/-3.8 mmHg (25.4%, P<0.001). The mean number of patient medications after 6 months was 0.5+/-0.8 medications, a mean decrease of 1.0+/-0.8 medications (66.7%, P<0.001). Most subjects (70%) were able to discontinue all glaucoma medications. There were no complications traditionally associated with filtering surgery, and no serious adverse events were reported.

Conclusion: In this interim analysis of subjects with glaucoma and cataracts, this novel stent implantation in subjects undergoing cataract surgery represents a new surgical approach to provide clinically significant decreases in IOP and drug burden.

PubMed Disclaimer

Publication types