Development of a tweezers-type coincidence imaging detector
- PMID: 18600416
- DOI: 10.1007/s12149-008-0114-7
Development of a tweezers-type coincidence imaging detector
Abstract
Objective: When employing F-18-fluorodeoxyglucose (FDG)-guided surgery to detect positron accumulation in isolated small organs, sampling these organs from opposite directions is a useful way of determining a tumor's position, similar to sampling a small organ with tweezers. The coincidence method is suitable for this purpose because only the positrons between two detectors can be detected. For this purpose, we developed a tweezers-type coincidence imaging detector.
Methods: The detector employs two depth-of-interaction (DOI) detectors positioned at the tip of the tweezers and images the positron distribution between them using the coincidence method. The DOI detector consists of a 4 x 3 Gd(2)SiO(5):Ce (GSO) array optically coupled to a one-dimensionally arranged quad-photomultiplier tube. These GSOs were arranged to form a DOI detector using the Anger principle. The useful field of view is 20 mm x 15 mm. With these configurations, we could resolve 4 x 3 GSO arrays on a position histogram.
Results: Because the imaging detectors were positioned at the tip of the tweezers, one could easily sample the target part manually from opposed sides. A real-time image in coincidence between these two DOI detectors could be obtained. The point spread functions were approximately 3-mm full width at half-maximum (FWHM) parallel to the tweezers and 4-mm FWHM perpendicular to them. The sensitivity was approximately 1% when the two imaging detectors were 10 mm apart.
Conclusions: With these results, we conclude that the developed tweezers-type imaging detector has a potential to be a new instrument in nuclear medicine.
Similar articles
-
Depth of interaction decoding of a continuous crystal detector module.Phys Med Biol. 2007 Apr 21;52(8):2213-28. doi: 10.1088/0031-9155/52/8/012. Epub 2007 Mar 29. Phys Med Biol. 2007. PMID: 17404465
-
Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes.Phys Med Biol. 2006 May 7;51(9):2131-42. doi: 10.1088/0031-9155/51/9/001. Epub 2006 Apr 10. Phys Med Biol. 2006. PMID: 16625031
-
Design of a very high-resolution small animal PET scanner using a silicon scatter detector insert.Phys Med Biol. 2007 Aug 7;52(15):4653-77. doi: 10.1088/0031-9155/52/15/019. Epub 2007 Jul 17. Phys Med Biol. 2007. PMID: 17634656
-
On the use of CCD area detectors for high-resolution specular X-ray reflectivity.J Synchrotron Radiat. 2006 Jul;13(Pt 4):293-303. doi: 10.1107/S0909049506018000. Epub 2006 Jun 15. J Synchrotron Radiat. 2006. PMID: 16799220 Review.
-
Positron emission tomography/computed tomography: the current technology and applications.Radiol Clin North Am. 2009 Jan;47(1):147-60. doi: 10.1016/j.rcl.2008.10.005. Radiol Clin North Am. 2009. PMID: 19195540 Review.
Cited by
-
Initial demonstration of the Scratch-PET concept: an intraoperative PET with a hand-held detector.Radiol Phys Technol. 2025 Jun;18(2):407-416. doi: 10.1007/s12194-025-00889-z. Epub 2025 Mar 12. Radiol Phys Technol. 2025. PMID: 40072801 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources