Quantification of and correction for left ventricular systolic long-axis shortening by magnetic resonance tissue tagging and slice isolation
- PMID: 1860217
- DOI: 10.1161/01.cir.84.2.721
Quantification of and correction for left ventricular systolic long-axis shortening by magnetic resonance tissue tagging and slice isolation
Abstract
Background: Measurement of regional left ventricular (LV) function is predicted on the ability to compare equivalent LV segments at different time points during the cardiac cycle. Standard techniques of short-axis acquisition in two-dimensional echocardiography, cine computed tomography, and standard magnetic resonance imaging (MRI) acquire images from a fixed plane and fail to compensate for through-plane motion. The shortening of the left ventricle along its long axis during systole results in planar images of two different levels of the ventricle, leading to error in any derived functional measurements. LV systolic long-axis motion was measured in 19 normal volunteers using MRI.
Methods and results: With a selective radio frequency (RF) tissue-tagging technique, three short-axis planes were labeled at end diastole and standard spin-echo images were acquired at end systole in the two- and four-chamber orientations. Persistence of the tags through systole allowed visualization of the intersecting short-axis tags in the long-axis images and allowed precise quantification of long-axis motion of the septum, lateral, anterior, and inferior walls at the base, mid, and apical LV levels. The total change in position along the long axis between end diastole and end systole was greatest at the base, which moved toward the apex 12.8 +/- 3.8 mm. The mid left ventricle moved 6.9 +/- 2.6 mm, and the apex was nearly stationary, moving only 1.6 +/- 2.2 mm (p less than 0.001). Having quantified the normal range of long-axis shortening, we developed a technique that isolates a slice of tissue between selective RF saturation planes at end diastole. Combining this with a wide end-systolic image slice, end-systolic images were acquired without contamination of signal from adjacent tissue moving into the imaging plane. This technique was validated in a moving phantom and in normal volunteers.
Conclusions: Significant LV systolic long-axis shortening exists, and this effect is seen the most at the base and the least at the apex. At a given ventricular level, shortening varied significantly according to location. A method using selective saturation pulses and gated spin-echo MRI automatically corrects for this motion and thus eliminates misregistration artifact from regional function analysis.
Similar articles
-
Magnetic resonance evaluation of regional left ventricular function. Effect of through-plane motion.Invest Radiol. 1992 Sep;27(9):681-5. doi: 10.1097/00004424-199209000-00004. Invest Radiol. 1992. PMID: 1399450
-
Noninvasive quantification of left ventricular rotational deformation in normal humans using magnetic resonance imaging myocardial tagging.Circulation. 1990 Apr;81(4):1236-44. doi: 10.1161/01.cir.81.4.1236. Circulation. 1990. PMID: 2317906
-
A study in ventricular-ventricular interaction. Single right ventricles compared with systemic right ventricles in a dual-chamber circulation.Circulation. 1995 Jul 15;92(2):219-30. doi: 10.1161/01.cir.92.2.219. Circulation. 1995. PMID: 7600654
-
Quantitative tagged magnetic resonance imaging of the normal human left ventricle.Top Magn Reson Imaging. 2000 Dec;11(6):359-71. doi: 10.1097/00002142-200012000-00005. Top Magn Reson Imaging. 2000. PMID: 11153703 Free PMC article. Review.
-
Assessment of systolic and diastolic LV function by MR myocardial tagging.Basic Res Cardiol. 1996;91 Suppl 2:23-8. doi: 10.1007/BF00795358. Basic Res Cardiol. 1996. PMID: 8957540 Review.
Cited by
-
Data-driven computational models of ventricular-arterial hemodynamics in pediatric pulmonary arterial hypertension.Front Physiol. 2022 Sep 7;13:958734. doi: 10.3389/fphys.2022.958734. eCollection 2022. Front Physiol. 2022. PMID: 36160862 Free PMC article.
-
Independently Trained Multi-Scale Registration Network Based on Image Pyramid.J Imaging Inform Med. 2024 Aug;37(4):1557-1566. doi: 10.1007/s10278-024-01019-8. Epub 2024 Mar 5. J Imaging Inform Med. 2024. PMID: 38441699 Free PMC article.
-
The Impact of Cardiac Motion on Aortic Valve Flow Used in Computational Simulations of the Thoracic Aorta.J Biomech Eng. 2016 Sep 1;138(9):0910011-09100111. doi: 10.1115/1.4033964. J Biomech Eng. 2016. PMID: 27367143 Free PMC article.
-
Heterogeneity of myocardial wall motion and thickening in the left ventricle evaluated with quantitative gated SPECT.J Nucl Cardiol. 2000 Jul-Aug;7(4):296-300. doi: 10.1067/mnc.2000.104958. J Nucl Cardiol. 2000. PMID: 10958270
-
The compression type of coronary artery motion in patients with ST-segment elevation acute myocardial infarction and normal controls: a case-control study.BMC Res Notes. 2011 Mar 7;4:51. doi: 10.1186/1756-0500-4-51. BMC Res Notes. 2011. PMID: 21385385 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous