Development of phase-contrast X-ray imaging techniques and potential medical applications
- PMID: 18602852
- DOI: 10.1016/j.ejmp.2008.05.006
Development of phase-contrast X-ray imaging techniques and potential medical applications
Abstract
A significant improvement over conventional attenuation-based X-ray imaging, which lacks contrast in small objects and soft biological tissues, is obtained by introducing phase-contrast imaging. As recently demonstrated, phase-contrast imaging is characterized by its extraordinary image quality, greatly enhanced contrast, and good soft tissue discrimination with very high spatial resolution down to the micron and even the sub-micron region. The rapid development of compact X-ray sources of high brightness, tuneability, and monochromaticity as well as high-resolution X-ray detectors with high quantum efficiency and improved computational methods is stimulating the development of a new generation of X-ray imaging systems for medical applications. The present paper reviews some intrinsic mechanisms, recent technical developments and potential medical applications of two-, three- and four-dimensional phase-contrast X-ray imaging. Challenging issues in current phase-contrast imaging techniques and key clinical applications are discussed and possible developments of future high-contrast and high spatial and temporal resolution medical X-ray imaging systems are outlined.
Similar articles
-
Grating-based X-ray phase contrast for biomedical imaging applications.Z Med Phys. 2013 Sep;23(3):176-85. doi: 10.1016/j.zemedi.2013.02.002. Epub 2013 Feb 28. Z Med Phys. 2013. PMID: 23453793 Review.
-
Complex dark-field contrast and its retrieval in x-ray phase contrast imaging implemented with Talbot interferometry.Med Phys. 2014 Oct;41(10):101914. doi: 10.1118/1.4896098. Med Phys. 2014. PMID: 25281966
-
Laboratory-based X-ray phase-contrast imaging technique for material and medical science applications.Appl Radiat Isot. 2008 Aug;66(8):1083-90. doi: 10.1016/j.apradiso.2007.12.008. Epub 2007 Dec 23. Appl Radiat Isot. 2008. PMID: 18313312
-
Quantitative comparison of imaging performance of x-ray interferometric imaging and diffraction enhanced imaging.Med Phys. 2008 Oct;35(10):4724-34. doi: 10.1118/1.2977543. Med Phys. 2008. PMID: 18975717
-
Quantitative X-ray phase contrast computed tomography with grating interferometry : Biomedical applications of quantitative X-ray grating-based phase contrast computed tomography.Eur J Nucl Med Mol Imaging. 2021 Dec;48(13):4171-4188. doi: 10.1007/s00259-021-05259-6. Epub 2021 Apr 13. Eur J Nucl Med Mol Imaging. 2021. PMID: 33846846 Free PMC article. Review.
Cited by
-
Are human peripheral nerves sensitive to X-ray imaging?PLoS One. 2015 Mar 10;10(3):e0116831. doi: 10.1371/journal.pone.0116831. eCollection 2015. PLoS One. 2015. PMID: 25757086 Free PMC article.
-
Glancing angle Talbot-Lau grating interferometers for phase contrast imaging at high x-ray energy.Appl Phys Lett. 2012 Aug 27;101(9):91108. doi: 10.1063/1.4748882. Epub 2012 Aug 28. Appl Phys Lett. 2012. PMID: 23024376 Free PMC article.
-
Ion migration and dark current suppression in quasi-2D perovskite-based X-ray detectors.RSC Adv. 2024 Jun 14;14(27):19124-19133. doi: 10.1039/d4ra02606c. eCollection 2024 Jun 12. RSC Adv. 2024. PMID: 38882481 Free PMC article.
-
Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging.Phys Med Biol. 2014 Apr 21;59(8):1877-97. doi: 10.1088/0031-9155/59/8/1877. Epub 2014 Mar 20. Phys Med Biol. 2014. PMID: 24651402 Free PMC article.
-
Dose and diagnostic performance comparison between phase-contrast mammography with synchrotron radiation and digital mammography: a clinical study report.J Med Imaging (Bellingham). 2018 Jan;5(1):013503. doi: 10.1117/1.JMI.5.1.013503. Epub 2018 Feb 1. J Med Imaging (Bellingham). 2018. PMID: 29430473 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials