Efficacy of sinonasal simulator in teaching endoscopic nasal skills
- PMID: 18607304
- DOI: 10.1097/MLG.0b013e3181772d4f
Efficacy of sinonasal simulator in teaching endoscopic nasal skills
Abstract
Objectives/hypothesis: To develop a nasal model (NM) which accurately simulates human texture and anatomy and to study the effect of training with NM on performance of video rigid nasal endoscopy and video flexible laryngoscopy. At the conclusion of this presentation, the participants should be able to demonstrate that training with nasal endoscopic simulation enhances efficiency and may improve comfort to the patient.
Study design: A randomized blinded control trial.
Methods: Twenty medical students without prior endoscopic experience, stratified by prior video game experience, were randomized to training or no training on NM. All participants viewed a 15-minute video instruction on endoscopy. Students randomized to training then practiced on the NM for 15 minutes. All students were tested within 90 minutes of the initial instruction with a timed identification of structures on NM followed by a timed flexible laryngoscopy on a human volunteer who ranked comfort/discomfort on a visual analogue scale.
Results: The students in the training group had a significantly shorter procedure time on NM using rigid nasal endoscopy compared with untrained students (61 seconds vs. 104 seconds, P = .025). The trained students showed a trend, which did not reach statistical significance, toward faster flexible laryngoscopy on the model (23 seconds vs. 32 seconds, P = .085). The trained students had average lower discomfort scores (0.89 vs. 1.33) compared with untrained students, but this did not reach statistical significance.
Conclusions: Our NM accurately simulates human texture and anatomy and provides an opportunity for endoscopic training without concern of bloodborne pathogens and expense of cadavers. Further development of the NM is warranted to expand the training utility.
Similar articles
-
Endoscopic Sinus Surgery Simulator as a teaching tool for anatomy education.Am J Surg. 2008 Jul;196(1):120-4. doi: 10.1016/j.amjsurg.2007.06.026. Epub 2008 Apr 2. Am J Surg. 2008. PMID: 18374890
-
The compactEASIE is a feasible training model for endoscopic novices: a prospective randomised trial.Dig Liver Dis. 2007 Jan;39(1):70-8; discussion 79-80. doi: 10.1016/j.dld.2006.07.007. Epub 2006 Aug 30. Dig Liver Dis. 2007. PMID: 16942923 Clinical Trial.
-
Simulation in ENT medical education.J Laryngol Otol. 2010 Mar;124(3):237-41. doi: 10.1017/S0022215109991885. Epub 2009 Dec 3. J Laryngol Otol. 2010. PMID: 19954561 Review.
-
Validation of computer-based training in ureterorenoscopy.BJU Int. 2005 Jun;95(9):1276-9. doi: 10.1111/j.1464-410X.2005.05518.x. BJU Int. 2005. PMID: 15892816
-
Currently available simulators: ex vivo models.Gastrointest Endosc Clin N Am. 2006 Jul;16(3):435-49. doi: 10.1016/j.giec.2006.03.010. Gastrointest Endosc Clin N Am. 2006. PMID: 16876716 Review.
Cited by
-
Face, content, and construct validation of a low-cost, non-biologic, sinus surgery task trainer and knowledge-based curriculum.Int Forum Allergy Rhinol. 2017 Apr;7(4):405-413. doi: 10.1002/alr.21883. Epub 2016 Nov 16. Int Forum Allergy Rhinol. 2017. PMID: 27865063 Free PMC article.
-
Surgical simulator for temporal bone dissection training.Braz J Otorhinolaryngol. 2010 Sep-Oct;76(5):575-8. doi: 10.1590/S1808-86942010000500007. Braz J Otorhinolaryngol. 2010. PMID: 20963339 Free PMC article.
-
Use of a Low-fidelity simulator to improve trans-nasal fibre-optic flexible laryngoscopy in the clinical setting: a randomized, single-blinded, prospective study.J Otolaryngol Head Neck Surg. 2013 May 21;42(1):35. doi: 10.1186/1916-0216-42-35. eCollection 2013. J Otolaryngol Head Neck Surg. 2013. PMID: 23688331 Free PMC article. Clinical Trial.
-
Real models and virtual simulators in otolaryngology: review of literature.Braz J Otorhinolaryngol. 2010 Jan-Feb;76(1):129-35. doi: 10.1590/S1808-86942010000100021. Braz J Otorhinolaryngol. 2010. PMID: 20339701 Free PMC article. Review.
-
Are sinonasal dissection courses a valid instrument for endoscopic sinus surgeons? A report on 7-years of experience.Acta Otorhinolaryngol Ital. 2020 Dec;40(6):415-420. doi: 10.14639/0392-100X-N0705. Acta Otorhinolaryngol Ital. 2020. PMID: 33558769 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical