Clinical experience in the use of photostimulable phosphor radiographic systems
- PMID: 1860768
- DOI: 10.1097/00004424-199106000-00017
Clinical experience in the use of photostimulable phosphor radiographic systems
Abstract
The experience with CR systems gained at the three institutions described in this report demonstrates numerous advantages over the conventional screen-film system. These include: (1) a reduction in the radiation exposure delivered to the patient (25% to 50%); (2) a decrease in the number of repeat examinations needed, especially in portable units where technical difficulties are common with screen-film examinations; this is attributable to the linear, wider dynamic range of CR systems compared with screen-film combinations; (3) the capability to archive electronically all images by means of a digital optical storage system; (4) automatic electronic setting of the laser scanner for the latitude and sensitivity on each image; (5) the digital images are available for transmission to all image display workstations on a local or wide-area network; and (6) the ability to adjust interactively the display parameters to best depict images and pathology as well as salvage technically suboptimal examinations. Several disadvantages of CR systems compared with conventional screen-film examinations have also been identified.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Comparison of a photostimulable phosphor system with film for dental radiology.Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1997 Jun;83(6):725-31. doi: 10.1016/s1079-2104(97)90327-9. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1997. PMID: 9195631
-
Chest radiographic image quality: comparison of asymmetric screen-film, digital storage phosphor, and digital selenium drum systems--preliminary study.Radiographics. 1998 May-Jun;18(3):745-54. doi: 10.1148/radiographics.18.3.9599395. Radiographics. 1998. PMID: 9599395
-
Use of computed radiography in the study of an historic painting.Radiographics. 1997 Nov-Dec;17(6):1487-95. doi: 10.1148/radiographics.17.6.9397460. Radiographics. 1997. PMID: 9397460
-
[Recent developments in x-ray luminescent imaging systems].Radiol Diagn (Berl). 1990;31(4):401-8. Radiol Diagn (Berl). 1990. PMID: 2236548 Review. German.
-
Digital imaging of the chest.Radiology. 1989 May;171(2):297-307. doi: 10.1148/radiology.171.2.2649913. Radiology. 1989. PMID: 2649913 Review.
Cited by
-
Hardware and software requirements for a picture archiving and communication system's diagnostic workstations.J Digit Imaging. 1992 May;5(2):107-17. doi: 10.1007/BF03167835. J Digit Imaging. 1992. PMID: 1623039
-
Enhancement of storage phosphor plate images: a C-language program.J Digit Imaging. 1992 Feb;5(1):59-63. doi: 10.1007/BF03167825. J Digit Imaging. 1992. PMID: 1554760
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources