Scaleup of spinfilter perfusion bioreactor for mammalian cell retention
- PMID: 18615610
- DOI: 10.1002/bit.260430209
Scaleup of spinfilter perfusion bioreactor for mammalian cell retention
Abstract
A spinning cylindrical filter, known as a spinfilter, permits the mammalian cell bioreactor operation at high perfusion rates leading to very high cell densities (10(7) mL(-1)). Filter screens with openings (25 mum) slightly larger than the average cell size have been used to retain single cells in suspension over a long period of operation without clogging. We have previously shown why it is necessary to optimize the rotational speed of the spinfilter in order to achieve efficient cell retention and avoid potential screen clogging. Effects of bulk mixing and perfusion rate on screen fouling and cell retention were also investigated. Based on this analysis, in this article, we suggest strategies for scaleup of spinfilters. Experimental data from 12- and 175-L (working volume) bioreactors is shown in support of the scaleup analysis.
Similar articles
-
Mammalian cell retention in a spinfilter perfusion bioreactor.Biotechnol Bioeng. 1992 Oct 20;40(8):925-33. doi: 10.1002/bit.260400809. Biotechnol Bioeng. 1992. PMID: 18601200
-
Practical considerations in operation and scale-up of spin-filter based bioreactors for monoclonal antibody production.Biotechnol Prog. 1996 Jan-Feb;12(1):57-64. doi: 10.1021/bp950079p. Biotechnol Prog. 1996. PMID: 8845109
-
Production of monoclonal antibodies for breast cancer by HB8696 hybridoma cells using novel perfusion system.Enzyme Microb Technol. 2014 Oct;64-65:44-51. doi: 10.1016/j.enzmictec.2014.07.002. Epub 2014 Jul 14. Enzyme Microb Technol. 2014. PMID: 25152416
-
Influence of alterations in culture condition and changes in perfusion parameters on the retention performance of a 20 mum spinfilter during a perfusion cultivation of a recombinant CHO cell line in pilot scale.Cytotechnology. 2000 Oct;34(1-2):141-50. doi: 10.1023/A:1008183508439. Cytotechnology. 2000. PMID: 19003388 Free PMC article.
-
Bioreactor scale-up and oxygen transfer rate in microbial processes: an overview.Biotechnol Adv. 2009 Mar-Apr;27(2):153-76. doi: 10.1016/j.biotechadv.2008.10.006. Epub 2008 Nov 12. Biotechnol Adv. 2009. PMID: 19041387 Review.
Cited by
-
Mammalian cell retention devices for stirred perfusion bioreactors.Cytotechnology. 1998 Nov;28(1-3):163-75. doi: 10.1023/A:1008050202561. Cytotechnology. 1998. PMID: 19003418 Free PMC article.
-
CFD simulation of an internal spin-filter: evidence of lateral migration and exchange flow through the mesh.Cytotechnology. 2009 Nov;61(1-2):55-64. doi: 10.1007/s10616-009-9242-8. Epub 2009 Dec 10. Cytotechnology. 2009. PMID: 19998058 Free PMC article.
LinkOut - more resources
Full Text Sources