Multicenter Study
. 2008 Nov;34(11):2100-5.
doi: 10.1007/s00134-008-1210-9. Epub 2008 Jul 11.

Safety and efficacy of ultrasound assistance during internal jugular vein cannulation in neurosurgical infants

Affiliations
Multicenter Study

Safety and efficacy of ultrasound assistance during internal jugular vein cannulation in neurosurgical infants

M Lamperti et al. Intensive Care Med. 2008 Nov.

Abstract

Objective: Ultrasound guidance (USG) for internal jugular cannulation is the best solution in difficult settings where paediatric patients are involved. This is an outcome study on efficacy and complications of the USG for the internal jugular vein (IJV) cannulation in neurosurgical infants as well as an ultrasound study of anatomical findings of the IJVs in infants.

Design and settings: A prospective study conducted in two Academic Neurosurgical hospitals.

Participants: In 191 babies (body weight <15 kg), anatomical findings were studied. We performed CVC echo guided placement in 135/191 infants (weighting <10 kg).

Results: After a brief training period, both institutions adopted a common protocol and USG device. We obtained successful cannulation in all patients. Carotid puncture (1.5%) was the only main complication registered and minor complications were poor. Time required for cannulation was 12.5 +/- 5.7 min. Anatomical findings (in 191 patients) were IJV laterality in 34.6% cases, IJV antero-lateral in 59.7% and anterior in 5.7%. A linear relation was found between weight and internal jugular vein diameter even if R(2) = 0.43 and the model cannot be used to predict the exact size of the vein. In 62/135 babies weighting <10 kg, anatomical measurements were done in supine and Trendelemburg position. Trendelemburg position increases significantly (P < 0.001) IJV diameter, but not IJV depth.

Conclusions: We considered ultrasound guidance as the first choice in infants because it can enhance IJV cannulation success, safety, and allows one to measure relationships and diameter of the IJV and optimise the central line positioning.

PubMed Disclaimer

References

    1. Anesthesiology. 1999 Jul;91(1):71-7 - PubMed
    1. Surg Gynecol Obstet. 1987 Sep;165(3):230-4 - PubMed
    1. J Cardiothorac Vasc Anesth. 2002 Oct;16(5):567-71 - PubMed
    1. Br J Anaesth. 1993 Feb;70(2):145-8 - PubMed
    1. Anesthesiology. 2004 Jun;100(6):1411-8 - PubMed

Publication types

LinkOut - more resources