Precision assessment of model-based RSA for a total knee prosthesis in a biplanar set-up
- PMID: 18635360
- DOI: 10.1016/j.knee.2008.05.001
Precision assessment of model-based RSA for a total knee prosthesis in a biplanar set-up
Abstract
Model-based Roentgen Stereophotogrammetric Analysis (RSA) was recently developed for the measurement of prosthesis micromotion. Its main advantage is that markers do not need to be attached to the implants as traditional marker-based RSA requires. Model-based RSA has only been tested in uniplanar radiographic set-ups. A biplanar set-up would theoretically facilitate the pose estimation algorithm, since radiographic projections would show more different shape features of the implants than in uniplanar images. We tested the precision of model-based RSA and compared it with that of the traditional marker-based method in a biplanar set-up. Micromotions of both tibial and femoral components were measured with both the techniques from double examinations of patients participating in a clinical study. The results showed that in the biplanar set-up model-based RSA presents a homogeneous distribution of precision for all the translation directions, but an inhomogeneous error for rotations, especially internal-external rotation presented higher errors than rotations about the transverse and sagittal axes. Model-based RSA was less precise than the marker-based method, although the differences were not significant for the translations and rotations of the tibial component, with the exception of the internal-external rotations. For both prosthesis components the precisions of model-based RSA were below 0.2 mm for all the translations, and below 0.3 degrees for rotations about transverse and sagittal axes. These values are still acceptable for clinical studies aimed at evaluating total knee prosthesis micromotion. In a biplanar set-up model-based RSA is a valid alternative to traditional marker-based RSA where marking of the prosthesis is an enormous disadvantage.
Similar articles
-
Clinical validation of model-based RSA for a total knee prosthesis.Clin Orthop Relat Res. 2007 Nov;464:205-9. Clin Orthop Relat Res. 2007. PMID: 18062052
-
A new type of model-based Roentgen stereophotogrammetric analysis for solving the occluded marker problem.J Biomech. 2005 Nov;38(11):2330-4. doi: 10.1016/j.jbiomech.2004.09.018. Epub 2004 Nov 11. J Biomech. 2005. PMID: 16154422
-
Trapeziometacarpal joint implants can be evaluated by roentgen stereophotogrammetric analysis.J Hand Surg Eur Vol. 2010 Jul;35(6):480-5. doi: 10.1177/1753193409355627. Epub 2010 Feb 24. J Hand Surg Eur Vol. 2010. PMID: 20181771
-
Roentgen stereophotogrammetric analysis of prosthetic fixation in the hip and knee joint.Clin Orthop Relat Res. 1992 Mar;(276):56-65. Clin Orthop Relat Res. 1992. PMID: 1537175 Review.
-
Roentgen stereophotogrammetric analysis.Acta Radiol. 1990 Mar;31(2):113-26. Acta Radiol. 1990. PMID: 2196921 Review.
Cited by
-
Dose reduction does not impact the precision of CT-based RSA in tibial implants: a diagnostic accuracy study on precision in a porcine cadaver.Acta Orthop. 2023 Oct 31;94:550-544. doi: 10.2340/17453674.2023.24022. Acta Orthop. 2023. PMID: 37909103 Free PMC article.
-
Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study.Eur Radiol Exp. 2021 Dec 15;5(1):55. doi: 10.1186/s41747-021-00253-x. Eur Radiol Exp. 2021. PMID: 34907467 Free PMC article.
-
Bone remodeling and implant migration of uncemented femoral and cemented asymmetrical tibial components in total knee arthroplasty - DXA and RSA evaluation with 2-year follow up.Knee Surg Relat Res. 2021 Aug 17;33(1):25. doi: 10.1186/s43019-021-00111-5. Knee Surg Relat Res. 2021. PMID: 34404487 Free PMC article.
-
Does a new knee design perform as well as the design it replaces?Bone Joint Res. 2012 Dec 1;1(12):315-23. doi: 10.1302/2046-3758.112.2000064. Print 2012 Dec. Bone Joint Res. 2012. PMID: 23610663 Free PMC article.
-
How do CAD models compare with reverse engineered manufactured components for use in wear analysis?Clin Orthop Relat Res. 2012 Jul;470(7):1847-54. doi: 10.1007/s11999-011-2143-0. Clin Orthop Relat Res. 2012. PMID: 22016002 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical