Noninvasive measurement of central venous pressure by neck inductive plethysmography
- PMID: 1864108
- DOI: 10.1378/chest.100.2.371
Noninvasive measurement of central venous pressure by neck inductive plethysmography
Abstract
Bedside estimation of the height at which the internal jugular veins collapse, referenced to a standard hemodynamic location, theoretically reflects central venous pressure. This method has never been demonstrated as accurate when compared to invasive CVP measurements because of the great clinical skills and time required to visually identify the internal jugular venous waveform. Since the principles of the bedside method are sound, we utilized them in conjunction with the neck inductive plethysmograph, a device which has the capability of recording internal jugular venous and carotid arterial waveforms. The respiratory distortion of these vascular waveforms was eliminated by employing a digital bandpass filter, making it easy to identify the venous and arterial waveforms on the videoscreen of a personal computer. The upper torso was positioned while observing the videoscreen until the vascular waveform was seen as a mixed arteriovenous waveform, signifying intermittent internal jugular venous collapse. The height of the internal jugular vein above the phlebostatic axis was obtained by external measurement and recorded as CVPni in cm H2O. In 43 patients, 86 percent of CVPni (NIP) values fell within 20 percent CVPi (invasive catheter measurements) over a range of CVP from 0 to 19 cm H2O. In an additional seven patients, CVPi was greater than the height that the upper torso could be elevated and an arterial waveform could not be obtained. Here, CVPni was recorded as the value at least exceeding the value measured. In two other patients, obstruction of an internal jugular vein gave spuriously low values of CVPni. Our study indicates that this new neck inductive plethysmographic method is accurate compared to invasive catheter measurements of CVP and should serve as a safe, noninvasive alternative in situations where such measurements are required.
Similar articles
-
Ultrasonographic assessment of the internal jugular vein for the estimation of central venous pressure in hemodialysis patients: A preliminary study.J Clin Ultrasound. 2018 May;46(4):253-258. doi: 10.1002/jcu.22571. Epub 2018 Jan 4. J Clin Ultrasound. 2018. PMID: 29314087 Clinical Trial.
-
New method for noninvasive quantification of central venous pressure by ultrasound.Circ Cardiovasc Imaging. 2015 May;8(5):e003085. doi: 10.1161/CIRCIMAGING.114.003085. Circ Cardiovasc Imaging. 2015. PMID: 25904575
-
Using central venous pressure waveform to confirm the placement of an internal jugular central venous catheter in the intensive care unit.Aust Crit Care. 2024 Jul;37(4):628-631. doi: 10.1016/j.aucc.2023.10.007. Epub 2023 Dec 7. Aust Crit Care. 2024. PMID: 38065796
-
Physical examination of venous pressure: a critical review.Am Heart J. 1998 Jul;136(1):10-8. doi: 10.1016/s0002-8703(98)70175-9. Am Heart J. 1998. PMID: 9665212 Review.
-
[Estimation of the jugular venous pressure].Ned Tijdschr Geneeskd. 2016;160:A9600. Ned Tijdschr Geneeskd. 2016. PMID: 26758360 Review. Dutch.
Cited by
-
Changing trends of hemodynamic monitoring in ICU - from invasive to non-invasive methods: Are we there yet?Int J Crit Illn Inj Sci. 2014 Apr;4(2):168-77. doi: 10.4103/2229-5151.134185. Int J Crit Illn Inj Sci. 2014. PMID: 25024945 Free PMC article.
-
How far is the sternal angle from the mid-right atrium?J Gen Intern Med. 2002 Nov;17(11):852-6. doi: 10.1046/j.1525-1497.2002.20101.x. J Gen Intern Med. 2002. PMID: 12406357 Free PMC article.
-
Comparison between noninvasive measurement of central venous pressure using near infrared spectroscopy with an invasive central venous pressure monitoring in cardiac surgical Intensive Care Unit.Ann Card Anaesth. 2016 Jul-Sep;19(3):405-9. doi: 10.4103/0971-9784.185520. Ann Card Anaesth. 2016. PMID: 27397443 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources