Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Dec;18(12):2817-25.
doi: 10.1007/s00330-008-1076-9. Epub 2008 Jul 19.

Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings

Affiliations
Comparative Study

Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings

Ingvar Andersson et al. Eur Radiol. 2008 Dec.

Abstract

The main purpose was to compare breast cancer visibility in one-view breast tomosynthesis (BT) to cancer visibility in one- or two-view digital mammography (DM). Thirty-six patients were selected on the basis of subtle signs of breast cancer on DM. One-view BT was performed with the same compression angle as the DM image in which the finding was least/not visible. On BT, 25 projections images were acquired over an angular range of 50 degrees, with double the dose of one-view DM. Two expert breast imagers classified one- and two-view DM, and BT findings for cancer visibility and BIRADS cancer probability in a non-blinded consensus study. Forty breast cancers were found in 37 breasts. The cancers were rated more visible on BT compared to one-view and two-view DM in 22 and 11 cases, respectively, (p < 0.01 for both comparisons). Comparing one-view DM to one-view BT, 21 patients were upgraded on BIRADS classification (p < 0.01). Comparing two-view DM to one-view BT, 12 patients were upgraded on BIRADS classification (p < 0.01). The results indicate that the cancer visibility on BT is superior to DM, which suggests that BT may have a higher sensitivity for breast cancer detection.

PubMed Disclaimer

References

    1. Radiology. 2000 May;215(2):554-62 - PubMed
    1. N Engl J Med. 2005 Oct 27;353(17):1773-83 - PubMed
    1. AJR Am J Roentgenol. 1992 Aug;159(2):287-94 - PubMed
    1. Med Phys. 2007 Feb;34(2):400-7 - PubMed
    1. Radiology. 2001 Mar;218(3):873-80 - PubMed

Publication types