Pure tone audiometry with and without specific ear protectors
- PMID: 18661017
- PMCID: PMC9442105
- DOI: 10.1016/s1808-8694(15)30577-2
Pure tone audiometry with and without specific ear protectors
Abstract
The authors evaluated pure tone audiometry with and without specific ear protectors.
Aim: The purpose of this case control study was to measure the level of sound attenuation by earplugs.
Material and methods: The evaluation included sixty ears of 30 subjects of both sexes, aged between 20 and 58 years, of various professional activities, with normal hearing thresholds, and following ten hours of auditory rest. The statistical results of pure tone audiometry at 500 to 4000 Hertz with and without specific ear protectors were analyzed.
Results: These results were compared with those provided by the ear protector manufacturer.
Conclusion: The results show that the rate of sound reduction was similar to the manufacturer's specifications.
Figures
References
-
- Curado JAF, et al. A incidência de PAIR na lavanderia de um hospital universitário. Arq otorrinolaringol. 2001;5(2):113–116.
-
- Russo ICP, et al. Um estudo comparativo sobre os efeitos da exposição a um Sica em músicos de trio elétrico. Rev Bras Otorrinolaringol. 1995;61(6):477–484.
-
- Nogueira DP. Introdução a Segurança, Higiene e Medicina do Trabalho. Curso de Medicina do Trabalho - Fundacentro. 1979;1:5–10.
-
- Abreu MT, Suzuki FA. Avaliação de trabalhadores ocupacionalmente expostos a ruído e cádmio. Rev Bras Otorrinolaringol. 2002;68(3):488–494.
-
- Suter AH, Lempert BL, Franks JRJ. Real-ear atenuation of earmuffs in normal hearing and hearing impaired Individuals. Acoust Soc Am. 1990;87(5):2114–2117. - PubMed
Uncited Reference
-
- Portaria do INSS com respeito à perda auditiva por ruído ocupacional D.O.num.131;11-07-97. secção3;pag 14244-49 Arq otorrinolaringol. 1977;1(3)
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources