Randomized Controlled Trial
. 2009 Jan;35(1):123-8.
doi: 10.1007/s00134-008-1236-z. Epub 2008 Jul 26.

Intensive insulin therapy: enhanced Model Predictive Control algorithm versus standard care

Affiliations
Randomized Controlled Trial

Intensive insulin therapy: enhanced Model Predictive Control algorithm versus standard care

Jeremy J Cordingley et al. Intensive Care Med. 2009 Jan.

Abstract

Objective: To investigate the effectiveness of an enhanced software Model Predictive Control (eMPC) algorithm for intravenous insulin infusion, targeted at tight glucose control in critically ill patients, over 72 h, in two intensive care units with different management protocols.

Design: Comparison with standard care in a two center open randomized clinical trial.

Setting: Two adult intensive care units in University Hospitals.

Patients and participants: Thirty-four critically ill patients with hyperglycaemia (glucose >120 mg/dL) or already receiving insulin infusion.

Interventions: Patients were randomized, within each ICU, to intravenous insulin infusion advised by eMPC algorithm or the ICU's standard insulin infusion administration regimen.

Measurements and results: Arterial glucose concentration was measured at study entry and when advised by eMPC or measured as part of standard care. Time-weighted average glucose concentrations in patients receiving eMPC advised insulin infusions were similar [104 mg/dL (5.8 mmol/L)] in both ICUs. eMPC advised glucose measurement interval was significantly different between ICUs (1.1 vs. 1.8 h, P < 0.01). The standard care insulin algorithms resulted in significantly different time-weighted average glucose concentrations between ICUs [128 vs. 99 mg/dL (7.1 vs. 5.5 mmol/L), P < 0.01].

Conclusions: In this feasibility study the eMPC algorithm provided similar, effective and safe tight glucose control over 72 h in critically ill patients in two different ICUs. Further development is required to reduce glucose sampling interval while maintaining a low risk of hypoglycaemia.