Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2008 Aug;109(2):255-8.
doi: 10.3171/JNS/2008/109/8/0255.

Effect of intracranial pressure on the diameter of the optic nerve sheath

Affiliations
Clinical Trial

Effect of intracranial pressure on the diameter of the optic nerve sheath

Arata Watanabe et al. J Neurosurg. 2008 Aug.

Abstract

Object: The subarachnoid space around the optic nerve in the orbit can be visualized using T2-weighted MR imaging with the fat-saturation pulse sequence. The optic nerve sheath (ONS) diameter can be estimated by measuring the outer diameter of the subarachnoid space. Dilated ONS is associated with idiopathic intracranial hypertension and hydrocephalus, and is believed to reflect increased intracranial pressure (ICP). The relationship between dilated ONS and ICP is unclear because of the difficulty in obtaining noninvasive measurements of ICP. The authors investigated the relationship between subdural pressure measured at the time of surgery and ONS diameter measured on MR images in patients with chronic subdural fluid collection.

Methods: Twelve patients underwent bur-hole craniostomy with continuous drainage for chronic subdural hematoma or hygroma in 2006. Orbital thin-slice fat-saturated MR images were obtained before and after surgery, and the ONS diameters were measured just behind the optic globe. Subdural pressure was measured using a manometer before opening of the dura mater.

Results: A significant correlation was found between the ONS diameter and the subdural pressure (correlation coefficient 0.879, p = 0.0036). The ONS diameter before surgery (6.1 +/- 0.7 mm) was significantly reduced after surgery (4.8 +/- 0.9 mm, p = 0.003; measurements are expressed as the mean +/- standard deviation).

Conclusions: Increased ONS diameter measured on coronal orbital thin-slice fat-saturated T2-weighted MR images is a strong indicator of increased ICP, and helps to differentiate between passive subdural fluid collection due to brain atrophy and subdural hygroma with increased ICP.

PubMed Disclaimer