Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2009 Dec;31(6):649-56.
doi: 10.1111/j.1751-553X.2008.01092.x. Epub 2008 Jul 31.

Sensitivity and specificity of Anti-HBc screening assays--which assay is best for blood donor screening?

Affiliations

Sensitivity and specificity of Anti-HBc screening assays--which assay is best for blood donor screening?

M K Hourfar et al. Int J Lab Hematol. 2009 Dec.

Abstract

Compared to HIV and hepatitis C virus, the residual infectious risk of hepatitis B virus (HBV) posed by blood products is about 10 times higher. In addition to HBsAg testing, screening for anti-HBc was recommended by the German Advisory Committee Blood in March 2005. Prevalence of anti-HBc in German blood donors was investigated at five test sites located in different geographic regions. In total, 12,000 blood donors were screened for anti-HBc by PRISM HBcore, and a statistically representative number of these were tested with Abbott Murex anti-HBc total, bioMérieux Hepanostika anti-HBc uniform, Bio-Rad Monolisa anti-HBc PLUS and Dade Behring Enzygnost anti-HBc. Anti-HBc repeat reactive samples were tested for anti-HBs, anti-HBe and HBV DNA by individual donation NAT. The mean prevalence of anti-HBc was 1.75% in donors that had not been tested for anti-HBc in the past. The percentage of anti-HBs in anti-HBc repeat reactive donors was 93.7%. Samples that were additionally reactive for anti-HBe were anti-HBc reactive in all tested assays. The sample to cut-off (S/Co) values for anti-HBc were lower (competitive assays) in samples that were also positive for anti-HBe, when compared to samples that were only anti-HBc reactive. Most commercially available anti-HBc assays provide sufficient sensitivity for routine screening purposes, and lacking specificity is no longer a serious issue for most of them. Assay differences were recognized for samples that were anti-HBc only reactive. The overall loss of 1.75% of positive testing donors can be significantly reduced to 0.45% by implementation of re-entry procedures for donors with an anti-HBs titre of over 100 IU/l and negative by sensitive ID-NAT.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources