Comparison of the model-based and marker-based roentgen stereophotogrammetry methods in a typical clinical setting
- PMID: 18676114
- DOI: 10.1016/j.arth.2008.02.004
Comparison of the model-based and marker-based roentgen stereophotogrammetry methods in a typical clinical setting
Abstract
Roentgen stereophotogrammetric analysis (RSA) is an established method for the precise measurement of implant migration. Model-based RSA (MBRSA) alleviates the need to attach tantalum markers to the prosthesis, which has prevented wider application of RSA. The goal of this study was to investigate the equivalence of both methods for the clinical measurement of implant migration. Tibial component migration was measured in 24 patients using both methods from the same set of radiographs. The maximum agreement interval, mean (+/-2 standard deviations), of the difference between both methods was modest, at 0.002 mm (0.144 mm) and -0.078 degrees (0.782 degrees ). The results suggest that MBRSA can be used interchangeably with the marker-based method and that the advantages of MBRSA do not come at the cost of a loss in accuracy.
Similar articles
-
Experimental analysis of Model-Based Roentgen Stereophotogrammetric Analysis (MBRSA) on four typical prosthesis components.J Biomech Eng. 2009 Apr;131(4):041004. doi: 10.1115/1.3072892. J Biomech Eng. 2009. PMID: 19275433
-
Accuracy of model-based RSA contour reduction in a typical clinical application.Clin Orthop Relat Res. 2008 Aug;466(8):1978-86. doi: 10.1007/s11999-008-0287-3. Epub 2008 May 29. Clin Orthop Relat Res. 2008. PMID: 18509712 Free PMC article. Clinical Trial.
-
Clinical validation of model-based RSA for a total knee prosthesis.Clin Orthop Relat Res. 2007 Nov;464:205-9. Clin Orthop Relat Res. 2007. PMID: 18062052
-
Roentgen stereophotogrammetric analysis.Acta Radiol. 1990 Mar;31(2):113-26. Acta Radiol. 1990. PMID: 2196921 Review.
-
Roentgen stereophotogrammetric analysis of prosthetic fixation in the hip and knee joint.Clin Orthop Relat Res. 1992 Mar;(276):56-65. Clin Orthop Relat Res. 1992. PMID: 1537175 Review.
Cited by
-
Validation of static and dynamic radiostereometric analysis of the knee joint using bone models from CT data.Bone Joint Res. 2017 Jun;6(6):376-384. doi: 10.1302/2046-3758.66.BJR-2016-0113.R3. Bone Joint Res. 2017. PMID: 28600383 Free PMC article.
-
Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.Acta Orthop. 2014 Sep;85(5):447-55. doi: 10.3109/17453674.2014.934187. Epub 2014 Jun 23. Acta Orthop. 2014. PMID: 24954489 Free PMC article.
-
In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.Med Biol Eng Comput. 2013 Mar;51(3):257-65. doi: 10.1007/s11517-012-0987-4. Epub 2012 Nov 11. Med Biol Eng Comput. 2013. PMID: 23143478
-
Dependence of model-based RSA accuracy on higher and lower implant surface model quality.Biomed Eng Online. 2013 Apr 16;12:32. doi: 10.1186/1475-925X-12-32. Biomed Eng Online. 2013. PMID: 23587251 Free PMC article.
-
Longitudinal migration and inducible displacement of the Mobility Total Ankle System.Acta Orthop. 2012 Aug;83(4):394-400. doi: 10.3109/17453674.2012.712890. Epub 2012 Aug 10. Acta Orthop. 2012. PMID: 22880712 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical