Simulated pivot-shift testing with single and double-bundle anterior cruciate ligament reconstructions
- PMID: 18676898
- DOI: 10.2106/JBJS.G.01272
Simulated pivot-shift testing with single and double-bundle anterior cruciate ligament reconstructions
Abstract
Background: One of the principal rationales for performing a double-bundle reconstruction of the anterior cruciate ligament is the suggestion that it may be superior to a single-bundle reconstruction in restoring a normal pivot-shift sign. The purpose of this study was to measure the abilities of single-bundle and anatomic double-bundle reconstructions to restore normal knee kinematics and graft forces during a simulated pivot-shift test.
Methods: Graft force and knee kinematics were recorded during a simulated pivot-shift event with and without the anterior cruciate ligament and after graft reconstructions. With a single bundle, the graft was tensioned to restore anterior-posterior laxity at 30 degrees of flexion. With double-bundle reconstructions, the anteromedial graft was first tensioned as above and then the posterolateral graft tension was set with use of one of four protocols: posterolateral tension = anteromedial tension at 10 degrees of flexion (DB1); posterolateral tension = anteromedial tension at 30 degrees (DB2); posterolateral tension = (anteromedial tension + 30 N) at 10 degrees (DB3); and posterolateral tension = (anteromedial tension + 30 N) at 30 degrees (DB4).
Results: A single-bundle reconstruction restored all displacements and rotations during the pivot shift to the intact knee levels. The mean tibial rotations and lateral plateau displacements during the pivot shift with DB2, DB3, and DB4 reconstructions were less than those in the intact knee and also less than those in a single-bundle reconstruction. Before the pivot shift, the mean graft forces with all reconstructions were greater than that of the intact knee; the mean graft forces with the DB3 and DB4 reconstructions were also greater than that of a single-bundle reconstruction. After the pivot shift, the mean graft forces for all reconstructions were less than the levels before the pivot shift with single-bundle forces lower than intact knee levels and DB4 forces higher than intact knee levels.
Conclusions: Reduction or elimination of the pivot-shift sign is an important goal for anterior cruciate ligament reconstruction. In our model, the results show that a single-bundle reconstruction was sufficient to restore intact knee kinematics during a simulated pivot-shift event. The higher graft forces with some double-bundle graft-tensioning protocols reduced the coupled rotations and displacements from an applied valgus moment to less than the intact levels. This overcorrection should theoretically make the knee less likely to pivot but could have unknown clinical consequences.
Similar articles
-
Anterior-posterior and rotatory stability of single and double-bundle anterior cruciate ligament reconstructions.J Bone Joint Surg Am. 2009 Jan;91(1):107-18. doi: 10.2106/JBJS.G.01215. J Bone Joint Surg Am. 2009. PMID: 19122085
-
How well do anatomical reconstructions of the posterolateral corner restore varus stability to the posterior cruciate ligament-reconstructed knee?Am J Sports Med. 2007 Jul;35(7):1117-22. doi: 10.1177/0363546507299240. Am J Sports Med. 2007. PMID: 17581975
-
Comparison of in situ forces and knee kinematics in anteromedial and high anteromedial bundle augmentation for partially ruptured anterior cruciate ligament.Am J Sports Med. 2011 Feb;39(2):272-8. doi: 10.1177/0363546510383479. Epub 2010 Dec 4. Am J Sports Med. 2011. PMID: 21131679
-
Review article: anatomic double bundle anterior cruciate ligament reconstruction.J Orthop Surg (Hong Kong). 2007 Aug;15(2):216-21. doi: 10.1177/230949900701500219. J Orthop Surg (Hong Kong). 2007. PMID: 17709865 Review.
-
In vitro and intraoperative laxities after single-bundle and double-bundle anterior cruciate ligament reconstructions.Arthroscopy. 2011 Jun;27(6):849-60. doi: 10.1016/j.arthro.2010.12.003. Arthroscopy. 2011. PMID: 21624681 Free PMC article. Review.
Cited by
-
A mechanical pivot-shift device for continuously applying defined loads to cadaveric knees.Knee Surg Sports Traumatol Arthrosc. 2015 Oct;23(10):2900-8. doi: 10.1007/s00167-015-3775-5. Epub 2015 Sep 10. Knee Surg Sports Traumatol Arthrosc. 2015. PMID: 26359176
-
Optimal measurement of clinical rotational test for evaluating anterior cruciate ligament insufficiency.Knee Surg Sports Traumatol Arthrosc. 2012 Jul;20(7):1323-30. doi: 10.1007/s00167-011-1643-5. Epub 2011 Aug 18. Knee Surg Sports Traumatol Arthrosc. 2012. PMID: 21850429
-
Electromagnetic tracking of the pivot-shift.Curr Rev Musculoskelet Med. 2016 Jun;9(2):164-9. doi: 10.1007/s12178-016-9335-x. Curr Rev Musculoskelet Med. 2016. PMID: 27007473 Free PMC article. Review.
-
Anterior cruciate ligament graft choices.Sports Health. 2012 Jan;4(1):63-8. doi: 10.1177/1941738111409890. Sports Health. 2012. PMID: 23016071 Free PMC article.
-
Mechanized pivot shift test achieves greater accuracy than manual pivot shift test.Knee Surg Sports Traumatol Arthrosc. 2010 Sep;18(9):1208-13. doi: 10.1007/s00167-009-1004-9. Epub 2009 Dec 15. Knee Surg Sports Traumatol Arthrosc. 2010. PMID: 20012937
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical