Suitable solutions for reconstituting the ultrasound contrast agent "Levovist" used in contrast echocardiogram: in vitro and in vivo evaluation of the influence of osmotic pressure
- PMID: 18678422
- DOI: 10.1016/j.ijcard.2008.05.043
Suitable solutions for reconstituting the ultrasound contrast agent "Levovist" used in contrast echocardiogram: in vitro and in vivo evaluation of the influence of osmotic pressure
Abstract
Purpose: To evaluate the influence of the osmotic pressure of solutions used for reconstituting the ultrasound contrast agent "Levovist" on the degree of video intensity of the enhancement and video intensity decay in contrast echocardiogram, we used 6 solutions with different osmotic pressures in both vitro and in vivo experiments.
Materials and methods: In the in vitro experiments, Levovist was reconstituted with 6 kinds of solutions with different osmotic pressures (Lactate Ringer's solution, 2.5%, 5%, 7.5%, and 20% glucose and distilled water) and peak video intensities and video intensity decay were measured. In the in vivo experiments, contrast echocardiography was performed in 7 adult volunteers, following the intravenous injections of Levovist, previously reconstituted with one of 2 solutions (5% glucose or distilled water).
Results: In vitro, at peak time, Levovist reconstituted with either Lactate Ringer's solution, 2.5% glucose, 5% glucose, or distilled water had good peak video intensities. At 30 s after peak time, Levovist reconstituted with Lactate Ringer's solution had greater enhancement and less decay than the other 5 solutions (P<0.001). In vivo, at 180 heart beats after peak time, the video intensity decay with 5% glucose was greater than that with distilled water (150+/-13 dB, 123+/-25 dB, respectively, P<0.05).
Conclusion: In this study, among various (2.5-20%) glucose solutions, the stability of the microbubbles differed, depending on the degree of osmotic pressure of the respective solutions; 5% glucose was the best. However, overall, the most suitable solution for reconstituting Levovist, was Lactate Ringer's solution. These findings could lead to effective strategies for better contrast echocardiography using Levovist by changing the current solution of choice to Lactate Ringer's solution or 5% glucose.
Similar articles
-
[Effect of oxygen inhalation on myocardial opacification using levovist: an animal experimental study].J Cardiol. 2001 Jun;37(6):335-40. J Cardiol. 2001. PMID: 11433809 Japanese.
-
Plasma glucose level in elective surgical patients administered with 5% dextrose in 0.45% NaCl in comparison with those receiving lactated Ringer's solution.J Med Assoc Thai. 2009 Sep;92(9):1178-83. J Med Assoc Thai. 2009. PMID: 19772177 Clinical Trial.
-
Compatibility of packed erythrocytes and Ringer's lactate solution.Surg Gynecol Obstet. 1991 Jul;173(1):9-12. Surg Gynecol Obstet. 1991. PMID: 1866680
-
[Intravenous contrast echocardiography].J Cardiol. 2000 Mar;35 Suppl 1:23-9. J Cardiol. 2000. PMID: 10834166 Review. Japanese.
-
[Levovist].Nihon Rinsho. 1998 Apr;56(4):876-80. Nihon Rinsho. 1998. PMID: 9577601 Review. Japanese.
Cited by
-
Stabilization of Gas Bubbles Released from Water-Soluble Carbohydrates Using Amphiphilic Compounds: Preparation of Formulations and Acoustic Monitoring of Bubble Lifetime.J Surfactants Deterg. 2011 Oct;14(4):585-593. doi: 10.1007/s11743-011-1250-y. Epub 2011 Feb 13. J Surfactants Deterg. 2011. PMID: 21957396 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous