. 2008 Aug 1;8(3):222-6.

Cardiac pacemaker battery discharge after external electrical cardioversion for broad QRS Complex Tachycardia

Affiliations

Cardiac pacemaker battery discharge after external electrical cardioversion for broad QRS Complex Tachycardia

Martino Annamaria et al. Indian Pacing Electrophysiol J. .

Abstract

External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical compromise, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete battery discharge was detected.

Keywords: Defibrillation; Electric countershock; Electromagnetic interference; Pacemaker; Ventricular arrhythmias.

PubMed Disclaimer

References

    1. Das G, Eaton J. Pacemaker malfunction following transthoracic countershock. PACE. 1981;4:487–490. - PubMed
    1. Erdogan Okan. Electromagnetic Interference on Pacemakers. Indian Pacing Electrophysiol J. 2002;2:74. - PMC - PubMed
    1. Salukhe TV, Dob D, Sutton R. Pacemakers and defibrillators: anaesthetic implications. British Journal of Anaesthesia. 2004;93:95–104. - PubMed
    1. Allen M. Pacemaker and implantable cardioverter defibrillators. Anaesthesia. 2006;61:883–890. - PubMed
    1. ACC/AHA/ESC Guidelines for management of patient with ventricular arrhythmias and the prevention of sudden cardiac death- Executive summary. JACC. 1999;48:1064–1108.

LinkOut - more resources