Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Nov;122(6):471-9.
doi: 10.1007/s00414-008-0274-y. Epub 2008 Aug 5.

Is post-mortem CT of the dentition adequate for correct forensic identification?: comparison of dental computed tomograpy and visual dental record

Affiliations
Comparative Study

Is post-mortem CT of the dentition adequate for correct forensic identification?: comparison of dental computed tomograpy and visual dental record

S Kirchhoff et al. Int J Legal Med. 2008 Nov.

Abstract

The gold standard for identification of the dead is the visual dental record. In this context, several authors emphasize computed tomography (CT) as valuable supportive tool for forensic medicine. However, studies focusing on diagnostic accuracy of post-mortem computed tomography (PMCT) are still missing. Therefore, the aim of this study was to compare diagnostic accuracy of the visual dental record and post-mortem computed tomography (PMCT) of the dentition for identification of the dead. Ten whole skulls were included into the study. The entire dentition of each skull was first examined with the visual dental record as a gold standard and second using dental PMCT scans, performed on a 64-multi-detector CT (MDCT). 3D reformations, multi-planar reformations (MPR), and CT-orthopantomography (OPG) were performed in the post-processing. All examinations were analyzed by three independent investigators regarding the criteria for identification of the dead, e.g., in case of disaster. PMCT for the dental identification of the dead was difficult to perform and time consuming. Due to dental overlays and corresponding artifacts, the definite periphery of the dental fillings/inlays was not accurately defined resulting in 2.9% incorrect and 64.1% false negative findings, especially synthetic inlays were hardly or not recognizable at all. For the identification of the dead especially in case of disasters with large numbers of victims, the visual dental record is still to be considered the gold standard. In the identification process itself, there is no room for error at all, although some non-concordant information may occur. Thus, PMCT should only be performed for identification in individual cases due to the relatively high error rate.

PubMed Disclaimer

References

    1. Int J Legal Med. 2006 Jan;120(1):24-6 - PubMed
    1. Int J Legal Med. 2008 Jan;122(1):1-5 - PubMed
    1. J Forensic Sci. 2006 Jan;51(1):113-9 - PubMed
    1. Int J Legal Med. 2005 Jan;119(1):27-30 - PubMed
    1. Dent Clin North Am. 2001 Apr;45(2):417-25 - PubMed

Publication types