Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2008 Sep-Oct;29(5):499-516.
doi: 10.2500/aap.2008.29.3147. Epub 2008 Aug 8.

Long-term safety and asthma control with budesonide/formoterol versus budesonide pressurized metered-dose inhaler in asthma patients

Affiliations
Clinical Trial

Long-term safety and asthma control with budesonide/formoterol versus budesonide pressurized metered-dose inhaler in asthma patients

Stephen P Peters et al. Allergy Asthma Proc. 2008 Sep-Oct.

Abstract

Safety concerns have been raised regarding the regular use of long-acting beta(2)-adrenergic agonists (LABAs) alone or with inhaled corticosteroids (ICSs). The purpose of this study was to examine the long-term safety of budesonide/formoterol pressurized metered-dose inhaler (pMDI). This 52-week, double-blind study (SD-039-0728; n=708) included patients >or=12 years of age with moderate to severe persistent asthma previously receiving ICSs. After 2 weeks on budesonide pMDI 320 microg twice daily (b.i.d.), patients were randomized 3:1:1 overall to budesonide/formoterol pMDI 640/18 microg b.i.d., budesonide/formoterol pMDI 320/9 microg b.i.d., or budesonide pMDI 640 microg b.i.d. The incidence of adverse events (AEs) was similar across the groups. Drug-related AEs (>or=2% overall) were oral candidiasis, tremor, and pharyngolaryngeal pain. No clinically meaningful differences in laboratory, electrocardiogram, or Holter monitor variables were observed. The percentage of patients with >or=1 asthma exacerbation was significantly lower (p=0.006) with budesonide/formoterol 640/18 (12.2%) and numerically lower with budesonide/formoterol 320/9 (14.4%) versus budesonide (21.8%). The number of asthma exacerbations per patient-treatment year was lower with budesonide/formoterol 640/18 (0.174; p=0.004) and budesonide/formoterol 320/9 (0.185; p=0.049) versus budesonide (0.315). Improvements in forced expiratory volume in 1 second and diary variables were significantly greater (p<0.001) with both budesonide/formoterol doses versus budesonide. Budesonide/formoterol 640/18 and 320/9 microg b.i.d. showed an acceptable safety profile relative to budesonide, with no significant or unexpected patterns of abnormalities observed by adding a LABA to budesonide for up to 1 year in this patient population. Improvements in asthma control were shown with both doses of budesonide/formoterol versus budesonide.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms