Picosecond-resolution fluorescence lifetime measuring system with a cw laser and a radio
- PMID: 18698934
- DOI: 10.1063/1.1135248
Picosecond-resolution fluorescence lifetime measuring system with a cw laser and a radio
Abstract
A procedure for measurement of fluorescence lifetimes with picosecond time resolution is described. A cw laser beam is modulated with a standing-wave acousto-optic modulator. The modulated beam is split; one part serves as a reference beam, the other part excites the fluorescent sample. The sample flourescence and the reference beam, attenuated and delayed optically to be equal in amplitude and opposite in phase to the fluorescence, are incident onto a single photomultiplier tube. The thus achieved photodetector ac null is monitored either by an AM radio, whose intermediate-frequency signal is displayed on an oscilloscope, or by a spectrum analyzer. With 30-MHz light modulation and the radio, lifetimes could be determined with resolution better than 15 ps. With the spectrum anlyzer and 170-MHz light modulation frequency we have achieved 4-ps lifetime resolution. Correction for photomultiplier transit time versus incident wavelength is made.
Similar articles
-
A phase-shift fluorometer using a laser and a transverse electrooptic modulator for subnanosecond lifetime measurements.Biophys J. 1977 Dec;20(3):335-42. doi: 10.1016/S0006-3495(77)85553-7. Biophys J. 1977. PMID: 922124 Free PMC article.
-
Autoregressive-model-based fluorescence-lifetime measurements by phase-modulation fluorometry using a pulsed-excitation light source and a high-gain photomultiplier tube.Appl Spectrosc. 2009 Nov;63(11):1256-61. doi: 10.1366/000370209789806911. Appl Spectrosc. 2009. PMID: 19891834
-
Rapid-scanning frequency-domain fluorometer with picosecond time resolution.Appl Opt. 1987 Sep 1;26(17):3526-9. doi: 10.1364/AO.26.003526. Appl Opt. 1987. PMID: 20490098
-
Digitally synthesized beat frequency-multiplexed fluorescence lifetime spectroscopy.Biomed Opt Express. 2014 Nov 26;5(12):4428-36. doi: 10.1364/BOE.5.004428. eCollection 2014 Dec 1. Biomed Opt Express. 2014. PMID: 25574449 Free PMC article.
-
Frequency domain fluorometry with pulsed light-emitting diodes.Ann N Y Acad Sci. 2008;1130:56-61. doi: 10.1196/annals.1430.026. Ann N Y Acad Sci. 2008. PMID: 18596332 Review.
Cited by
-
Luminescence Decay Dynamics and Trace Biomaterials Detection Potential of Surface-Functionalized Nanoparticles.J Phys Chem C Nanomater Interfaces. 2008 Oct 22;112(46):17931-17939. doi: 10.1021/jp8065647. J Phys Chem C Nanomater Interfaces. 2008. PMID: 20072713 Free PMC article.
-
Wearable device for remote monitoring of transcutaneous tissue oxygenation.Biomed Opt Express. 2020 Nov 9;11(12):6989-7002. doi: 10.1364/BOE.408850. eCollection 2020 Dec 1. Biomed Opt Express. 2020. PMID: 33408975 Free PMC article.
LinkOut - more resources
Full Text Sources