Assistive control system using continuous myoelectric signal in robot-aided arm training for patients after stroke
- PMID: 18701384
- DOI: 10.1109/TNSRE.2008.926707
Assistive control system using continuous myoelectric signal in robot-aided arm training for patients after stroke
Abstract
In some stroke rehabilitation programs, robotic systems have been used to aid the patient to train. In this study, a myoelectrically controlled robotic system with 1 degree-of-freedom was developed to assist elbow training in a horizontal plane with intention involvement for people after stroke. The system could provide continuous assistance in extension torque, which was proportional to the amplitude of the subject's electromyographic (EMG) signal from the triceps, and could provide resistive torques during movement. This study investigated the system's effect on restoring the upper limb functions of eight subjects after chronic stroke in a twenty-session rehabilitation training program. In each session, there were 18 trials comprising different combinations of assistive and resistive torques and an evaluation trial. Each trial consisted of five cycles of repetitive elbow flexion and extension between 90 degrees and 0 degrees at a constant velocity of 10 degrees/s. With the assistive extension torque, subjects could reach a more extended position in the first session. After 20 sessions of training, there were statistically significant improvements in the modified Ashworth scale, Fugl-Meyer scale for shoulder and elbow, motor status scale, elbow extension range, muscle strength, and root mean square error between actual elbow angle and target angle. The results showed that the twenty-session training program improved upper limb functions.
Similar articles
-
Effects of electromyography-driven robot-aided hand training with neuromuscular electrical stimulation on hand control performance after chronic stroke.Disabil Rehabil Assist Technol. 2015 Mar;10(2):149-59. doi: 10.3109/17483107.2013.873491. Epub 2013 Dec 31. Disabil Rehabil Assist Technol. 2015. PMID: 24377757
-
Myoelectrically controlled wrist robot for stroke rehabilitation.J Neuroeng Rehabil. 2013 Jun 10;10:52. doi: 10.1186/1743-0003-10-52. J Neuroeng Rehabil. 2013. PMID: 23758925 Free PMC article. Clinical Trial.
-
The therapeutic effects of myoelectrically controlled robotic system for persons after stroke--a pilot study.Conf Proc IEEE Eng Med Biol Soc. 2006;2006:4945-8. doi: 10.1109/IEMBS.2006.260186. Conf Proc IEEE Eng Med Biol Soc. 2006. PMID: 17946664
-
Robot-mediated upper limb physiotherapy: review and recommendations for future clinical trials.Int J Rehabil Res. 2011 Sep;34(3):196-202. doi: 10.1097/MRR.0b013e328346e8ad. Int J Rehabil Res. 2011. PMID: 21543990 Review.
-
Robot-aided neurorehabilitation: a robot for wrist rehabilitation.IEEE Trans Neural Syst Rehabil Eng. 2007 Sep;15(3):327-35. doi: 10.1109/TNSRE.2007.903899. IEEE Trans Neural Syst Rehabil Eng. 2007. PMID: 17894265 Free PMC article. Review.
Cited by
-
Advanced Myoelectric Control for Robotic Hand-Assisted Training: Outcome from a Stroke Patient.Front Neurol. 2017 Mar 20;8:107. doi: 10.3389/fneur.2017.00107. eCollection 2017. Front Neurol. 2017. PMID: 28373860 Free PMC article.
-
The Influence of EMG-Triggered Robotic Movement on Walking, Muscle Force and Spasticity after an Ischemic Stroke.Medicina (Kaunas). 2021 Mar 2;57(3):227. doi: 10.3390/medicina57030227. Medicina (Kaunas). 2021. PMID: 33801295 Free PMC article.
-
A High-Level Control Algorithm Based on sEMG Signalling for an Elbow Joint SMA Exoskeleton.Sensors (Basel). 2018 Aug 2;18(8):2522. doi: 10.3390/s18082522. Sensors (Basel). 2018. PMID: 30072609 Free PMC article.
-
A Neuromuscular Electrical Stimulation (NMES) and robot hybrid system for multi-joint coordinated upper limb rehabilitation after stroke.J Neuroeng Rehabil. 2017 Apr 26;14(1):34. doi: 10.1186/s12984-017-0245-y. J Neuroeng Rehabil. 2017. PMID: 28446181 Free PMC article.
-
A BMI-based occupational therapy assist suit: asynchronous control by SSVEP.Front Neurosci. 2013 Sep 23;7:172. doi: 10.3389/fnins.2013.00172. eCollection 2013. Front Neurosci. 2013. PMID: 24068982 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical