Arterial pulse pressure variation predicting fluid responsiveness in critically ill patients
- PMID: 18704014
- DOI: 10.1097/SHK.0b013e3181818708
Arterial pulse pressure variation predicting fluid responsiveness in critically ill patients
Retraction in
-
Auler JO Jr, Galas FR, Sundin MR, Hajjar LA: Arterial pulse pressure variation predicting fluid responsiveness in critically ill patients. Shock 30(Suppl 1):18-22, 2008.Shock. 2009 May;31(5):542. doi: 10.1097/SHK.0b013e3181a2e492. Shock. 2009. PMID: 19365234 No abstract available.
Abstract
In critically ill patients, it is important to predict which patients will have their systemic blood flow increased in response to volume expansion to avoid undesired hypovolemia and fluid overloading. Static parameters such as the central venous pressure, the pulmonary arterial occlusion pressure, and the left ventricular end-diastolic dimension cannot accurately discriminate between responders and nonresponders to a fluid challenge. In this regard, respiratory-induced changes in arterial pulse pressure have been demonstrated to accurately predict preload responsiveness in mechanically ventilated patients. Some experimental and clinical studies confirm the usefulness of arterial pulse pressure as a useful tool to guide fluid therapy in critically ill patients.
Similar articles
-
Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure.Crit Care Med. 2008 Oct;36(10):2810-6. doi: 10.1097/CCM.0b013e318186b74e. Crit Care Med. 2008. PMID: 18766099
-
Online monitoring of pulse pressure variation to guide fluid therapy after cardiac surgery.Anesth Analg. 2008 Apr;106(4):1201-6, table of contents. doi: 10.1213/01.ane.0000287664.03547.c6. Anesth Analg. 2008. PMID: 18349193
-
Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients.Crit Care Med. 2009 Mar;37(3):951-6. doi: 10.1097/CCM.0b013e3181968fe1. Crit Care Med. 2009. PMID: 19237902
-
Emerging trends in minimally invasive haemodynamic monitoring and optimization of fluid therapy.Eur J Anaesthesiol. 2009 Nov;26(11):893-905. doi: 10.1097/EJA.0b013e3283308e50. Eur J Anaesthesiol. 2009. PMID: 19667998 Review.
-
Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity.Curr Opin Crit Care. 2008 Jun;14(3):334-9. doi: 10.1097/MCC.0b013e3282fd6e1e. Curr Opin Crit Care. 2008. PMID: 18467896 Review.
Cited by
-
Changes in pulse pressure following fluid loading: a comparison between aortic root (non-invasive tonometry) and femoral artery (invasive recordings).Intensive Care Med. 2011 Jun;37(6):942-9. doi: 10.1007/s00134-011-2154-z. Epub 2011 Mar 5. Intensive Care Med. 2011. PMID: 21380524
-
Does stroke volume variation predict fluid responsiveness in children: A systematic review and meta-analysis.PLoS One. 2017 May 12;12(5):e0177590. doi: 10.1371/journal.pone.0177590. eCollection 2017. PLoS One. 2017. PMID: 28498858 Free PMC article.
-
Right internal jugular vein distensibility appears to be a surrogate marker for inferior vena cava vein distensibility for evaluating fluid responsiveness.Rev Bras Ter Intensiva. 2015 Jul-Sep;27(3):205-11. doi: 10.5935/0103-507X.20150042. Rev Bras Ter Intensiva. 2015. PMID: 26465243 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources