Early tissue incorporation and collagen deposition in lightweight polypropylene meshes: bioassay in an experimental model of ventral hernia
- PMID: 18707041
- DOI: 10.1016/j.surg.2008.04.005
Early tissue incorporation and collagen deposition in lightweight polypropylene meshes: bioassay in an experimental model of ventral hernia
Abstract
Background: This study was designed to assess the early host tissue incorporation of several polypropylene lightweight (PP-LW) meshes used to repair abdominal wall defects and to correlate collagen deposition with the biomechanical response shown by PP-LW versus polypropylene heavyweight (PP-HW) meshes.
Methods: Ventral hernial defects (7 x 5 cm) were created in the anterior abdominal wall of New Zealand rabbits and repaired by fixing PP-LW mesh of different pore sizes or a low porosity HW mesh to the edges of the defect. Rabbits were killed 14 days after implant, and specimens were taken from the central mesh area to examine collagen deposition by light microscopy, real time reverse transcription polymerase chain reaction, immunohistochemistry, and Western blotting. The biomechanical resistance of the biomaterials was also assessed.
Results: All the materials showed excellent incorporation in host tissue. Relative amounts of collagen III mRNA were considerably higher than collagen I mRNA. Higher collagen I and III mRNA levels were noted for pore sizes equal to or greater than 3.45 +/- 0.19 mm(2) (Ultrapro/Optilene Elastic. These two meshes showed significantly higher levels of collagen III than Parietene and Surgipro with smaller pores. Biomechanical resistance values for Optilene were significantly higher than those recorded for Surgipro and Parietene.
Conclusions: (a) LW meshes of pore size larger than 3 mm(2) induced the genetic overexpression of collagen types I and III; (b) the larger pore-sized LW meshes induced more collagen type III deposition and its faster conversion to collagen I; (c) Optilene, the most porous LW mesh examined, showed the greatest tensile strength 14 days after implant.
Similar articles
-
The long-term behavior of lightweight and heavyweight meshes used to repair abdominal wall defects is determined by the host tissue repair process provoked by the mesh.Surgery. 2012 Nov;152(5):886-95. doi: 10.1016/j.surg.2012.03.009. Epub 2012 May 8. Surgery. 2012. PMID: 22575883
-
Textile analysis of heavy weight, mid-weight, and light weight polypropylene mesh in a porcine ventral hernia model.J Surg Res. 2006 Nov;136(1):1-7. doi: 10.1016/j.jss.2006.05.022. Epub 2006 Sep 22. J Surg Res. 2006. PMID: 16996087
-
Partially absorbable meshes for hernia repair offer advantages over nonabsorbable meshes.Am J Surg. 2007 Jul;194(1):68-74. doi: 10.1016/j.amjsurg.2006.11.016. Am J Surg. 2007. PMID: 17560912
-
[Development of better tolerated prosthetic materials: applications in gynecological surgery].J Gynecol Obstet Biol Reprod (Paris). 2002 Oct;31(6):527-40. J Gynecol Obstet Biol Reprod (Paris). 2002. PMID: 12407323 Review. French.
-
[The problem of mesh shrinkage in laparoscopic incisional hernia repair].Zentralbl Chir. 2009 Jun;134(3):209-13. doi: 10.1055/s-0028-1098779. Epub 2009 Jun 17. Zentralbl Chir. 2009. PMID: 19536713 Review. German.
Cited by
-
Early and late postoperative inflammatory and collagen deposition responses in three different meshes: an experimental study in rats.Hernia. 2014 Aug;18(4):563-70. doi: 10.1007/s10029-013-1206-4. Epub 2013 Dec 27. Hernia. 2014. PMID: 24370605
-
Multicentric observational study of pain after the use of a self-gripping lightweight mesh.Hernia. 2011 Oct;15(5):511-5. doi: 10.1007/s10029-011-0811-3. Epub 2011 Mar 25. Hernia. 2011. PMID: 21437614
-
Randomized clinical trial of laparoscopic hernia repair comparing titanium-coated lightweight mesh and medium-weight composite mesh.Surg Endosc. 2013 Jan;27(1):231-9. doi: 10.1007/s00464-012-2425-y. Epub 2012 Jul 7. Surg Endosc. 2013. PMID: 22773233 Clinical Trial.
-
Inflammatory reaction and neotissue maturation in the early host tissue incorporation of polypropylene prostheses.Hernia. 2012 Dec;16(6):697-707. doi: 10.1007/s10029-012-0945-y. Epub 2012 Jun 29. Hernia. 2012. PMID: 22744412
-
Mesh graft infection following abdominal hernia repair: risk factor evaluation and strategies of mesh graft preservation. A retrospective analysis of 476 operations.World J Surg. 2010 Jul;34(7):1702-9. doi: 10.1007/s00268-010-0543-z. World J Surg. 2010. PMID: 20372901
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous