Modelling of heat and mass transfer processes in neonatology
- PMID: 18708705
- DOI: 10.1088/1748-6041/3/3/034113
Modelling of heat and mass transfer processes in neonatology
Abstract
This paper reviews some of our recent applications of computational fluid dynamics (CFD) to model heat and mass transfer problems in neonatology and investigates the major heat and mass transfer mechanisms taking place in medical devices such as incubators and oxygen hoods. This includes novel mathematical developments giving rise to a supplementary model, entitled infant heat balance module, which has been fully integrated with the CFD solver and its graphical interface. The numerical simulations are validated through comparison tests with experimental results from the medical literature. It is shown that CFD simulations are very flexible tools that can take into account all modes of heat transfer in assisting neonatal care and the improved design of medical devices.
Similar articles
-
An overview of recent applications of computational modelling in neonatology.Philos Trans A Math Phys Eng Sci. 2010 Jun 13;368(1920):2817-34. doi: 10.1098/rsta.2010.0052. Philos Trans A Math Phys Eng Sci. 2010. PMID: 20439275 Free PMC article. Review.
-
A combined study of heat and mass transfer in an infant incubator with an overhead screen.Med Eng Phys. 2007 Jun;29(5):531-41. doi: 10.1016/j.medengphy.2006.07.011. Epub 2006 Oct 9. Med Eng Phys. 2007. PMID: 17030142
-
Heat and mass transfer under an infant radiant warmer--development of a numerical model.Med Eng Phys. 2010 Jun;32(5):497-504. doi: 10.1016/j.medengphy.2010.02.021. Epub 2010 Mar 31. Med Eng Phys. 2010. PMID: 20356778
-
Electrically heated simulator for relative evaluation of alternative infant incubator environments.Med Instrum. 1988 Feb;22(1):33-8. Med Instrum. 1988. PMID: 3357463
-
[Heat exchanges and thermoregulation in the neonate].Arch Pediatr. 2009 Jul;16(7):1057-62. doi: 10.1016/j.arcped.2009.03.014. Epub 2009 May 1. Arch Pediatr. 2009. PMID: 19410440 Review. French.
Cited by
-
Assessment of radiant temperature in a closed incubator.Eur J Appl Physiol. 2012 Aug;112(8):2957-68. doi: 10.1007/s00421-011-2265-9. Epub 2011 Dec 10. Eur J Appl Physiol. 2012. PMID: 22160156 Free PMC article.
-
Assessing neonatal heat balance and physiological strain in newborn infants nursed under radiant warmers in intensive care with fentanyl sedation.Eur J Appl Physiol. 2014 Dec;114(12):2539-49. doi: 10.1007/s00421-014-2964-0. Epub 2014 Aug 13. Eur J Appl Physiol. 2014. PMID: 25115506
-
An overview of recent applications of computational modelling in neonatology.Philos Trans A Math Phys Eng Sci. 2010 Jun 13;368(1920):2817-34. doi: 10.1098/rsta.2010.0052. Philos Trans A Math Phys Eng Sci. 2010. PMID: 20439275 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous