Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Sep 15;80(18):7012-21.
doi: 10.1021/ac800920h. Epub 2008 Aug 21.

Optimized time alignment algorithm for LC-MS data: correlation optimized warping using component detection algorithm-selected mass chromatograms

Affiliations

Optimized time alignment algorithm for LC-MS data: correlation optimized warping using component detection algorithm-selected mass chromatograms

Christin Christin et al. Anal Chem. .

Abstract

Correlation optimized warping (COW) based on the total ion current (TIC) is a widely used time alignment algorithm (COW-TIC). This approach works successfully on chromatograms containing few compounds and having a well-defined TIC. In this paper, we have combined COW with a component detection algorithm (CODA) to align LC-MS chromatograms containing thousands of biological compounds with overlapping chromatographic peaks, a situation where COW-TIC often fails. CODA is a variable selection procedure that selects mass chromatograms with low noise and low background (so-called "high-quality" mass chromatograms). High-quality mass chromatograms selected in each COW segment ensure that the same compounds (based on their mass and their retention time) are used in the two-dimensional benefit function of COW to obtain correct and optimal alignments (COW-CODA). The performance of the COW-CODA algorithm was evaluated on three types of complex data sets obtained from the LC-MS analysis of samples commonly used for biomarker discovery and compared to COW-TIC using a new global comparison method based on overlapping peak area: trypsin-digested serum obtained from cervical cancer patients, trypsin-digested serum from a single patient that was treated with varying preanalytical parameters (factorial design study), and urine from pregnant and nonpregnant women. While COW-CODA did result in minor misalignments in rare cases, it was clearly superior to the COW-TIC algorithm, especially when applied to highly variable chromatograms (factorial design, urine). The presented algorithm thus enables automatic time alignment and accurate peak matching of multiple LC-MS data sets obtained from complex body fluids that are often used for biomarker discovery.

PubMed Disclaimer

Publication types

LinkOut - more resources