Objective: The purpose of our study is to review the accuracy of our method of non-imaging-guided anterior glenohumeral gadolinium contrast injection targeting the rotator interval in 100 consecutive patients.
Materials and methods: One hundred consecutive community-referred patients at our MRI facility underwent non-imaging-guided glenohumeral contrast injection targeting the rotator interval, with no patients excluded on the basis of expected diagnosis. The studies were then retrospectively reviewed for accuracy of injection based on patient factors and diagnosis.
Results: This method was 99% accurate in our study, regardless of diagnosis.
Conclusion: The relative ease, efficiency, reproducibility, and accuracy of this method of non-imaging-guided anterior glenohumeral injection make it the method of choice at our institution, and we believe this technique merits consideration for more widespread utilization.
Similar articles
-
All-in-one magnetic resonance arthrography of the shoulder in a vertically open magnetic resonance unit.Acta Radiol. 2008 Oct;49(8):918-27. doi: 10.1080/02841850802291242. Acta Radiol. 2008. PMID: 18651257 Clinical Trial.
-
Comparison of ultrasound versus fluoroscopic guided rotator cuff interval approach for MR arthrography.Clin Imaging. 2013 May-Jun;37(3):548-53. doi: 10.1016/j.clinimag.2012.08.002. Epub 2012 Sep 13. Clin Imaging. 2013. PMID: 23601770 Clinical Trial.
-
Arthrography of the shoulder: a modified ultrasound guided technique of joint injection at the rotator interval.Eur J Radiol. 2010 Jun;74(3):e29-32. doi: 10.1016/j.ejrad.2009.03.020. Epub 2009 Apr 25. Eur J Radiol. 2010. PMID: 19394776
-
MR arthrography of the shoulder: glenohumeral ligaments.JBR-BTR. 2009 Jan-Feb;92(1):48-53. JBR-BTR. 2009. PMID: 19358488 Review.
-
MR imaging of the shoulder: imaging techniques and anatomy.JBR-BTR. 2000 Dec;83(6):309-12. JBR-BTR. 2000. PMID: 11210684 Review.
Cited by
-
Diagnostic Performance of MR Arthrography with Anterior Trans-Subscapularis versus Posterior Injection Approach for Subscapularis Tendon Tears at 3.0T.Eur Radiol. 2017 Mar;27(3):1303-1311. doi: 10.1007/s00330-016-4467-3. Epub 2016 Jun 16. Eur Radiol. 2017. PMID: 27311539
-
Magnetic resonance arthrography of the glenohumeral joint: ultrasonography-guided technique using a posterior approach.Eurasian J Med. 2012 Aug;44(2):73-8. doi: 10.5152/eajm.2012.18. Eurasian J Med. 2012. PMID: 25610213 Free PMC article.
-
Comparison of accuracy of anterior and superomedial approaches to shoulder injection: an experimental study.SICOT J. 2016 Mar 25;2:13. doi: 10.1051/sicotj/2015044. SICOT J. 2016. PMID: 27163102 Free PMC article.
-
Extra-articular contrast material leaks into locations unrelated to the injection path in shoulder MR arthrography.Eur Radiol. 2014 Oct;24(10):2606-13. doi: 10.1007/s00330-014-3270-2. Epub 2014 Jun 25. Eur Radiol. 2014. PMID: 24962827
-
Ultrasound-guided injection through the rotator cuff interval: a clinical perspective of one institution's results and description of technique.J Osteopath Med. 2023 Aug 18;123(12):571-576. doi: 10.1515/jom-2023-0129. eCollection 2023 Dec 1. J Osteopath Med. 2023. PMID: 37589664
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical