Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2008 Dec 1;24(4):742-7.
doi: 10.1016/j.bios.2008.06.058. Epub 2008 Jul 12.

Synergie between molecular imprinted polymer based on solid-phase extraction and quartz crystal microbalance technique for 8-OHdG sensing

Affiliations

Synergie between molecular imprinted polymer based on solid-phase extraction and quartz crystal microbalance technique for 8-OHdG sensing

Arzu Ersöz et al. Biosens Bioelectron. .

Abstract

Recently, the 8-hydroxy-2'-deoxyguanosine (8-OHdG) has been used as a marker to determine the oxidative stress. There is no any cheap and easy determination method based on chips and sensor systems for the determination of 8-OHdG. In this study, we have proposed imprinting methods for 8-OHdG recognition and determination using methacryloylamidohistidine-platinum(II) [MAH-Pt(II)] as a new metal-chelating monomer. The study includes the solid-phase extraction (SPE) of blood sample by a new 8-OHdG imprinted sorbent and the measurement of binding interaction of 8-OHdG imprinted quartz crystal microbalance (QCM) sensor via ligand interaction. 8-OHdG imprinted sorbent has prepared by bulk polymerization of MAH-Pt(II) and N-N'-methylenebisacrylamide. 8-OHdG imprinted sensor has prepared on a QCM chip coating the thiol pretreated Au electrode. At the end of these steps, a thin molecular imprinted polymer (MIP) film for the detection of 8-OHdG has developed and analytical performance of QCM sensor which has prepared using MIP was investigated. The affinity constant (K(a)) for 8-OHdG using MAH-Pt-based thin film has determined by using the Scatchard method. The average percentage recovery of 8-OHdG from plasma samples was found as 80% by using of 8-OHdG imprinted SPE material. At the last step, 8-OHdG level in several blood plasma has been determined by this improved QCM sensor. The obtained results confirmed that the 8-OHdG level in cancer patient's blood was significantly higher than in general subjects.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources