Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2008 Oct;42(9):1040-6.
doi: 10.1097/MCG.0b013e31815853e0.

Plastic versus self-expanding metallic stents for malignant hilar biliary obstruction: a prospective multicenter observational cohort study

Affiliations
Comparative Study

Plastic versus self-expanding metallic stents for malignant hilar biliary obstruction: a prospective multicenter observational cohort study

David G Perdue et al. J Clin Gastroenterol. 2008 Oct.

Abstract

Background: There are few comparative data as to whether plastic or self-expanding metallic stents are preferable for palliating malignant hilar biliary obstruction.

Methods: Thirty-day outcomes of consecutive endoscopic retrograde cholangiopancreatographies performed for malignant hilar obstruction at 6 private and 5 university centers were assessed prospectively.

Results: Patients receiving plastic (N=28) and metallic stents (N=34) were similar except that metallic stent recipients more often had: Bismuth III or IV tumors (16/34 vs. 5/28 P=0.043), higher Charlson comorbidity scores (P=0.003), metastatic disease (P=0.006), and management at academic centers (P=0.018). The groups had similar rates of bilateral stent placement (4/28 vs. 5/34), and similar frequency of opacified but undrained segmental ducts (7/28 vs. 5/34). Adverse outcomes including cholangitis, stent occlusion, migration, perforation, and/or the need for unplanned endoscopic retrograde cholangiopancreatography or percutaneous transhepatic cholangiography occurred in 11/28 (39.3%) patients with plastic versus 4/34 (11.8%) with metal stents (P=0.017). By logistic regression, factors associated with adverse outcomes included plastic stent placement (odds ratio 6.32; 95% confidence interval 1.23, 32.56) and serum bilirubin (1.11/mg/dL above normal: 1.01, 1.22) but not center type or Bismuth class.

Conclusions: Metallic stent performance was superior to plastic for hilar tumor palliation with respect to short-term outcomes, independent of disease severity, Bismuth class, or drainage quality.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources