Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1991 May 15;63(10):1032-8.
doi: 10.1021/ac00010a020.

Direct determination of phospholipid structures in microorganisms by fast atom bombardment triple quadrupole mass spectrometry

Affiliations

Direct determination of phospholipid structures in microorganisms by fast atom bombardment triple quadrupole mass spectrometry

M J Cole et al. Anal Chem. .

Abstract

When phospholipids ionized by fast atom bombardment undergo collisionally induced dissociation (CID), they cleave at specific bonds between the functional groups contained on the lipid. These cleavages are common to all classes of phospholipids. By taking advantage of this fact, a general scheme has been developed that uses a triple-quadrupole mass spectrometer to rapidly characterize the phospholipid content and structures present in crude lipid extracts. This scheme is based on fast atom bombardment ionization of a crude lipid extract and on the combination of positive-ion neutral-loss and parent scans and negative-ion daughter scans. Neutral-loss and parent scans provide independent diagnostic mass spectra for each of many specific phospholipid classes, while daughter scans provide the emperical formulas and positions of the fatty acyl constituents on each phospholipid. An automated tandem mass spectrometry (MS/MS) instrument can perform an extensive phospholipid screening on a single sample. A useful mass profile of the phosphatidylethanolamine species present in a 1-pg sample of mixed phospholipids (equivalent to ten Escherichia coli cells) has been obtained. The spectra are reproducible and proportional to concentration over at least the five-logarithm range of cell concentrations studied. A rapid extraction procedure combined with the automated instrument control program produces profiles of the phospholipid classes, along with fatty acyl empirical formulas and position information, on selected phospholipid species, in a few minutes, from a single sample.

PubMed Disclaimer

Publication types

MeSH terms