Determination of left ventricular systolic wall thickness by digital subtraction angiography
- PMID: 1874257
- DOI: 10.1093/oxfordjournals.eurheartj.a059943
Determination of left ventricular systolic wall thickness by digital subtraction angiography
Abstract
The accuracy of digital subtraction angiography (DSA) for determination of left ventricular (LV) systolic wall thickness and muscle mass was evaluated in 20 patients (mean age 50 +/- 11 years). Conventional LV angiograms were digitized and subtracted using a combined subtraction mode ('mask mode' and 'time interval difference' subtraction). Wall thickness and muscle mass were determined at end-diastole, after the first- and second-third of systole and at end-systole. M-mode echocardiography (Echo), which was obtained from beam selection of the two-dimensional echocardiogram and conventional angiography (LVA), served as reference techniques. Angiographic LV wall thickness and muscle mass were determined according to the technique of Rackley in both, right (RAO) and left (LAO) anterior oblique projections, whereas echocardiographic wall thickness was measured just below the mitral valve orthogonal to the posterior wall (= LAO equivalent). Percent wall thickening was calculated in all patients. LV end-diastolic wall thickness and muscle mass correlated well between DSA and LVA (LV end-diastolic wall thickness in LAO projection r = 0.72, biplane LV end-diastolic muscle mass r = 0.83), LV end-systolic wall thickness (1.44 vs 1.33 cm, P less than 0.05) and percent wall thickening (52 vs 42%, P less than 0.05) compared favourably between echocardiography and DSA but was significantly larger when echocardiographically measured than with DSA (LAO projection). DSA and echocardiography showed a good correlation in regard to LV end-diastolic and end-systolic wall thickness (correlation coefficient r = 0.89, standard error of estimate SEE = 0.15 cm or 13% of the mean value).(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Left ventricular wall thickness measurements by magnetic resonance: a validation study.Int J Card Imaging. 1991;7(1):31-41. doi: 10.1007/BF01797678. Int J Card Imaging. 1991. PMID: 1753157
-
Determination of left ventricular wall thickness and muscle mass by intravenous digital subtraction angiocardiography: validation of the method.Eur Heart J. 1988 Jan;9(1):73-86. Eur Heart J. 1988. PMID: 3278909
-
Estimation of left ventricular chamber and stroke volume by limited M-mode echocardiography and validation by two-dimensional and Doppler echocardiography.Am J Cardiol. 1996 Oct 1;78(7):801-7. doi: 10.1016/s0002-9149(96)00425-0. Am J Cardiol. 1996. PMID: 8857486 Clinical Trial.
-
Two-dimensional echocardiography with a 15-MHz transducer is a promising alternative for in vivo measurement of left ventricular mass in mice.J Am Soc Echocardiogr. 1999 Jan;12(1):70-5. doi: 10.1016/s0894-7317(99)70175-6. J Am Soc Echocardiogr. 1999. PMID: 9882781
-
Effect of filming projection and interobserver variability on angiographic biplane left ventricular volume determination.Circulation. 1979 Jan;59(1):96-104. doi: 10.1161/01.cir.59.1.96. Circulation. 1979. PMID: 758129
Cited by
-
Detection of Cardiac Function Abnormality from MRI Images Using Normalized Wall Thickness Temporal Patterns.Int J Biomed Imaging. 2016;2016:4301087. doi: 10.1155/2016/4301087. Epub 2016 Mar 1. Int J Biomed Imaging. 2016. PMID: 27034648 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources