Measurement of human cerebral blood flow with [15O]butanol and positron emission tomography
- PMID: 1874804
- DOI: 10.1038/jcbfm.1991.127
Measurement of human cerebral blood flow with [15O]butanol and positron emission tomography
Abstract
Although H2(15)O is widely used for CBF measurement by positron tomography, it underestimates CBF, especially at elevated flow rates. Several tracers, including butanol, overcome this problem, but the short half-life of 15O provides advantages that cause water to remain the tracer of choice. We report the first use and evaluation of 15O-labeled butanol for CBF measurement. Flow measurements made in a similar fashion with water and butanol at 10-min intervals were compared in normal volunteers under resting and hypercapnic conditions. Regional analysis showed good agreement between the tracers at low flows, and significant underestimation of flow by water relative to butanol in regions of elevated flow. The observed relationship between the tracers and the curve-fitted permeability-surface area product for water (133 ml.100 g-1.min-1) follow the known relationship between water and true flow. These observations indicate that [15O]-butanol provided accurate measurements of human regional CBF under conditions of elevated perfusion. We conclude that butanol is a convenient and accurate method for routine CBF determination by positron emission tomography.
Similar articles
-
Positron emission tomographic measurement of cerebral blood flow and permeability-surface area product of water using [15O]water and [11C]butanol.J Cereb Blood Flow Metab. 1987 Oct;7(5):527-42. doi: 10.1038/jcbfm.1987.102. J Cereb Blood Flow Metab. 1987. PMID: 3498732
-
Measurement of regional cerebral blood flow with positron emission tomography: a comparison of [15O]water to [11C]butanol with distributed-parameter and compartmental models.J Cereb Blood Flow Metab. 1993 Sep;13(5):733-47. doi: 10.1038/jcbfm.1993.94. J Cereb Blood Flow Metab. 1993. PMID: 8360280
-
Quantitation of regional cerebral blood flow with 15O-butanol and positron emission tomography in humans.J Cereb Blood Flow Metab. 1996 Jul;16(4):645-9. doi: 10.1097/00004647-199607000-00015. J Cereb Blood Flow Metab. 1996. PMID: 8964804
-
Radioactive oxygen-15 in the study of cerebral blood flow, blood volume, and oxygen metabolism.Semin Nucl Med. 1985 Oct;15(4):377-94. doi: 10.1016/s0001-2998(85)80015-5. Semin Nucl Med. 1985. PMID: 3904006 Review.
-
Functional neuroanatomy of the human brain: positron emission tomography--a new neuroanatomical technique.J Anat. 1994 Apr;184 ( Pt 2)(Pt 2):211-25. J Anat. 1994. PMID: 8014115 Free PMC article. Review.
Cited by
-
Total-Body Perfusion Imaging with [11C]-Butanol.J Nucl Med. 2023 Nov;64(11):1831-1838. doi: 10.2967/jnumed.123.265659. Epub 2023 Aug 31. J Nucl Med. 2023. PMID: 37652544 Free PMC article.
-
A scoping review of the discrepancies in the measurement of cerebral blood flow in idiopathic intracranial hypertension: oligemia, euvolemia or hyperemia?Fluids Barriers CNS. 2023 Aug 23;20(1):63. doi: 10.1186/s12987-023-00465-w. Fluids Barriers CNS. 2023. PMID: 37612708 Free PMC article.
-
Fully Automated Radiosynthesis of No-Carrier-Added [11C]Butanol Using the GE FASTLab 2 Module.J Labelled Comp Radiopharm. 2025 Jul;68(9-10):e4158. doi: 10.1002/jlcr.4158. J Labelled Comp Radiopharm. 2025. PMID: 40745626 Free PMC article.
-
Individual somatotopy of primary sensorimotor cortex revealed by intermodal matching of MEG, PET, and MRI.Brain Topogr. 1992 Winter;5(2):183-7. doi: 10.1007/BF01129048. Brain Topogr. 1992. PMID: 1489648
-
Visual form discrimination from color or motion cues: functional anatomy by positron emission tomography.Proc Natl Acad Sci U S A. 1994 Oct 11;91(21):9965-9. doi: 10.1073/pnas.91.21.9965. Proc Natl Acad Sci U S A. 1994. PMID: 7937927 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous